Skip to main content
Schneider Electric ATV6B0C50T4 — AC Drive (VFD) 480V

Schneider ATV6B0C50T4 Altivar Process Drive, 700 HP, 480 V

MPNATV6B0C50T4
Active

Schneider Electric Altivar Process ATV600, ATV6B0C50T4, 700 hp normal duty / 600 hp heavy duty at 480 V, 674 A / 578 A line current, modular version with integrated EMC C3 filter.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6B0C50T4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6B0
Product range / familyAltivar Process ATV600

Power & Output

ATV6B0C50T4 — Power & Output
ParameterValue
Motor power (kW)500.0 kW at 480 V normal duty 400.0 kW at 480 V heavy duty
Continuous output current900.0 A at 2.5 kHz normal duty 730.0 A at 2.5 kHz heavy duty
Max. transient current990 A 60 s normal duty) 1095 A 60 s heavy duty)
Apparent power561 kVA at 480 V normal duty 480 kVA at 480 V heavy duty

Input / Supply

ATV6B0C50T4 — Input / Supply
ParameterValue
Rated supply voltage range480 V - 10...10 %
Input line current674.0 A 480 V normal duty) 578.0 A 480 V heavy duty)
Network number of phases3 phases

Control & Performance

ATV6B0C50T4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor Synchronous reluctance motor

Protection & EMC

ATV6B0C50T4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA

Mechanical & Cooling

ATV6B0C50T4 — Mechanical & Cooling
ParameterValue
Degree of protection (IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Acoustic noise level75 dB 86/188/EEC
Cooling methodForced convection

Environmental

ATV6B0C50T4 — Environmental
ParameterValue
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Operating altitude1000...4800 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2 IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

Approvals

ATV6B0C50T4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Communication

ATV6B0C50T4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

Drive for heavy motor loads – 700 hp at 480 V

The ATV6B0C50T4 is a modular Altivar Process drive rated for 700 hp normal duty and 600 hp heavy duty at 480 V, delivering 561 kVA and 480 kVA respectively. Line current pulls 674 A under normal duty, 578 A for heavy duty – sized for 400 kW / 500 kW motors. Prospective line Isc is 50 kA, so it's ready for high-fault-capacity installations. Modular version means the power module, control unit, and mounting kits ship as a single order code – no separate part hunting for the base unit. Cab enclosure: UL type 1 or type 12 when properly integrated into a cabinet.

Communication, safety, and cooling

Slot A accepts a full set of fieldbus option cards: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen. Slot A/B also take digital/analog I/O or relay extensions. Serial connection is RS-485 Modbus RTU at 4.8 to 38.4 kbit/s; Ethernet port runs 10/100 Mbit/s with auto-negotiation. Safe Torque Off (STO) is SIL 3 rated – integrates into a safety circuit without external contactors. Protection set includes thermal, overcurrent, short-circuit, phase loss, DC bus overvoltage/undervoltage, and overspeed. Cooling is forced convection; derate switching frequency from 2.5–8 kHz above 1000 m altitude. Vibration resistance: 1.5 mm p-p at 2–13 Hz, 0.5 gn at 13–200 Hz. Shock: 4 gn for 11 ms. Pollution degree 2 – suitable for typical industrial cabinet environments. Ambient relative humidity 5–95% non-condensing.

Compliance, lifecycle, and sourcing posture

For a BOM freeze or line expansion, the ATV6B0C50T4 is spec'd with a known lifecycle status – no pending PCN. Sourced to order; lead time is quoted per request. No direct drop-in substitute exists in the ATV600 family at this power class; alternative sizing would step up or down in frame, not pin-compatible.

Frequently asked questions

What is the closest pin-compatible alternative to ATV6B0C50T4 in this component family?

No pin-compatible alternative is documented in the ATV600 modular series. Lower or higher power variants use different power modules and frame sizes, so a direct swap is not available.

What is ATV6B0C50T4's listed marking (CE) on this component line?

The marking is CE.

What is ATV6B0C50T4's listed variant (Modular version) on this component line?

The variant is Modular version – meaning the drive is supplied as a kit including control unit, power module, mounting hardware, and connection fuses.

What compliance documentation does this brand provide for ATV6B0C50T4 (RoHS, REACH, UL, IEC)?

The drive complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. UL listings are for type 1 and type 12 enclosures under UL 61800-5-1. RoHS and REACH declarations are not explicitly stated in this evidence, but the CE marking implies European compliance for the applicable directives.

MPN
ATV6B0C50T4