Skip to main content
Schneider Electric ATV6B0C71T4 — AC Drive (VFD) 480V

Schneider ATV6B0C71T4 Altivar Process Drive, 1000 HP, 480 V,

MPNATV6B0C71T4
Active

Schneider Electric Altivar Process ATV600, modular version, ATV6B0C71T4, 1000 hp (710 kW) normal duty at 480 V, integrated EMC filter C3, STO SIL 3.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6B0C71T4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6B0
Product range / familyAltivar Process ATV600

Power & Output

ATV6B0C71T4 — Power & Output
ParameterValue
Motor power (kW)710.0 kW at 480 V normal duty 560.0 kW at 480 V heavy duty
Continuous output current1260.0 A at 2.5 kHz normal duty 1020.0 A at 2.5 kHz heavy duty
Max. transient current1386 A 60 s normal duty) 1530 A 60 s heavy duty)
Apparent power797 kVA at 480 V normal duty 641 kVA at 480 V heavy duty

Input / Supply

ATV6B0C71T4 — Input / Supply
ParameterValue
Rated supply voltage range480 V - 10...10 %
Input line current958.0 A 480 V normal duty) 771.0 A 480 V heavy duty)
Network number of phases3 phases

Control & Performance

ATV6B0C71T4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor Synchronous reluctance motor

Protection & EMC

ATV6B0C71T4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA

Mechanical & Cooling

ATV6B0C71T4 — Mechanical & Cooling
ParameterValue
Degree of protection (IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Acoustic noise level78 dB 86/188/EEC
Cooling methodForced convection

Environmental

ATV6B0C71T4 — Environmental
ParameterValue
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Operating altitude1000...4800 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2 IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

Approvals

ATV6B0C71T4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Communication

ATV6B0C71T4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

The ATV6B0C71T4 is a modular Altivar Process ATV600 drive from Schneider Electric, rated for 1000 hp (710 kW) normal duty and 800 hp (560 kW) heavy duty at 480 V. It lands in the ATV6B0 chassis, cabinet-mounted, with forced convection cooling. Line current draws 958 A in normal duty and 771 A in heavy duty at 480 V. An integrated EMC filter meets IEC 61800-3 category C3 for cable runs up to 300 m. Current total harmonic distortion stays under 5% at full load per IEEE 519. The drive handles both synchronous and asynchronous motors, with adjustable switching frequency from 2.5 to 8 kHz (derated above 2.5 kHz). Braking to standstill via DC injection.

Protection covers motor phase break, output short-circuit, DC bus overvoltage, line undervoltage, and more. Pollution degree 2 per IEC 61800-5-1 means the drive is suitable for control rooms and clean industrial environments; not for dusty or wet locations without additional enclosure. Vibration resistance is 1.5 mm peak-to-peak at 2–13 Hz, 0.5 gn at 13–200 Hz – standard for cabinet-mounted gear. Prospective line short-circuit current (Isc) rated at 50 kA – install on a supply with available fault current up to that value without upstream fusing for SCCR.

Communication slots A accept fieldbus modules for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, and CANopen. The onboard Modbus serial runs RTU at 4.8–38.4 kbit/s. Ethernet port (10/100 Mbit/s) supports half/full duplex and auto-negotiation.

Frequently asked questions

What are the key motor power ratings?

Normal duty: 1000 hp (710 kW) at 480 V. Heavy duty: 800 hp (560 kW) at 480 V. Line currents are 958 A and 771 A respectively.

What fieldbus options are available?

Slot A accepts Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, and CANopen (RJ45, SUB-D 9, or screw terminals). Onboard serial is Modbus RTU at up to 38.4 kbit/s.

MPN