Skip to main content
Schneider Electric ATV6B0M10R4 — AC Drive (VFD) 480V

Schneider ATV6B0M10R4 Altivar Process Drive, 1000 kW ND

MPNATV6B0M10R4
Active

Schneider Electric Altivar Process ATV600, modular drive, ATV6B0M10R4, 1000 kW at 440 V normal duty, 800 kW heavy duty, STO SIL 3, integrated EMC filter C3.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

ATV6B0M10R4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6B0
Product range / familyAltivar Process ATV600
ATV6B0M10R4 — Power & Output
ParameterValue
Motor power (kW)1000.0 kW at 440 V normal duty 800.0 kW at 440 V heavy duty
Continuous output current1770.0 A at 2.5 kHz normal duty 1420.0 A at 2.5 kHz heavy duty
Max. transient current1947 A during 60 s (normal duty) 2130 A during 60 s (heavy duty)
Apparent power1073 kVA at 440 V normal duty 858 kVA at 440 V heavy duty
ATV6B0M10R4 — Input / Supply
ParameterValue
Rated supply voltage range440 V - 15...10 %
Input line current1408.0 A at 440 V (normal duty) 1126.0 A at 440 V (heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), <200 mA, protection type: overload and short-circuit protection
ATV6B0M10R4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor Synchronous reluctance motor
ATV6B0M10R4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated with 300 m conforming to IEC 61800-3 category C3
Protection functionsThermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA
ATV6B0M10R4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529
Acoustic noise level79 dB conforming to 86/188/EEC
Cooling methodForced convection
ATV6B0M10R4 — Environmental
ParameterValue
Operating ambient temperature-10...40 °C without derating 40...50 °C with derating factor
Operating altitude0...4800 m with current derating above 1000m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV6B0M10R4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
ATV6B0M10R4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

The Schneider Electric ATV6B0M10R4 is an Altivar Process ATV600 modular drive rated for 1000 kW at 440 V normal duty and 800 kW at 440 V heavy duty, with a corresponding line current of 1408 A normal duty or 1126 A heavy duty at 440 V. It is a current-production unit (lifecycle stage: current) built for cabinet mounting with forced convection cooling. The drive draws its control power from an external 24 V DC supply (19...30 V) for digital inputs and an internal 24 V DC supply (21...27 V, <200 mA) for digital inputs and STO, with overload and short-circuit protection. It also provides a 10.5 V DC +/- 5 % reference supply for a 1 to 10 kOhm potentiometer. Integrated EMC filter meets IEC 61800-3 category C3 for 300 m of motor cable, and total harmonic current distortion stays under 5 % at full load per IEEE 519.

Safety and compliance

Safe torque off (STO) is built in at SIL 3, with dedicated 24 V DC inputs (STOA, STOB) compliant to IEC 61131-2 type 1 PLC levels. The drive carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. Pollution degree 2 per IEC 61800-5-1, operating altitude up to 4800 m with current derating above 1000 m, and relative humidity 5...95 % without condensation.

Integration and I/O

Three software-configurable analog inputs (AI1, AI2, AI3) accept 0...10 V DC or 0...20 mA/4...20 mA, 12-bit resolution, with linearity error +/- 0.15 % of max value. Two analog outputs (AO1, AO2) with +/- 0.2 % linearity. Six programmable digital inputs (DI1...DI6), with DI5 and DI6 configurable as pulse inputs up to 30 kHz. Three relay outputs: R1 is a configurable NO/NC fault relay, R2 and R3 are NO sequence relays, all rated for 100,000 cycles electrical durability. Relay response time is 5 ms +/- 0.5 ms. Slot A accepts communication option modules: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (daisy chain RJ45, SUB-D 9, or screw terminals). Slots A and B also accept digital/analog I/O extension modules or output relay extension modules.

Fieldbus and diagnostics

Embedded Modbus serial (2-wire RS-485, RTU format, 4.8 to 38.4 kbit/s) and Modbus TCP slave via Ethernet (10/100 Mbit/s, half/full duplex or autonegotiation). Local diagnostic LEDs: three for drive status, three dual-color for embedded communication, four dual-color for the communication module. The kit includes one control unit, mechanical mounting kits, power connection set of fuses, six 160 kW power modules, and a front cover.

Frequently asked questions

What safety functions does the ATV6B0M10R4 include?

It includes Safe Torque Off (STO) certified to SIL 3, with dedicated 24 V DC inputs for STOA and STOB.

What communication options are available for the ATV6B0M10R4?

Embedded Modbus serial and Modbus TCP. Slot A accepts Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen modules.

What is the maximum motor cable length with the integrated EMC filter?

The integrated EMC filter is rated for 300 m of motor cable, conforming to IEC 61800-3 category C3.

MPN
ATV6B0M10R4