Skip to main content
Schneider Electric ATV930C11N4C — AC Drive (VFD) 480V

Schneider ATV930C11N4C Altivar Process VFD, 110 kW, 211 A

MPNATV930C11N4C
Active

Schneider Electric Altivar Process ATV900 series, ATV930C11N4C variable speed drive, 3-phase 380-480 V, 110 kW normal duty / 90 kW heavy duty, 211 A nominal output current, IP21, UL Type 1 enclosure, wall-mount.

$6,211.57Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV930C11N4C — Identification
ParameterValue
Product typeVariable speed drive
Product range / familyAltivar Process ATV900
ATV930C11N4C — Power & Output
ParameterValue
Motor power (kW)110.0 kW normal duty 90.0 kW heavy duty
Continuous output current211 A 2.5 kHz normal duty 173 A 2.5 kHz heavy duty
ATV930C11N4C — Input / Supply
ParameterValue
Rated supply voltage range380...480 V
Internal/auxiliary suppliesExternal supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm 500 V DC for 1 minute to earth
ATV930C11N4C — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated With EMC plate option
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
ATV930C11N4C — Mechanical & Cooling
ParameterValue
Degree of protection (IP)UL type 1
IP degree of protectionIP21
Acoustic noise level69.9 dB
Assembly / installation styleEnclosed
ATV930C11N4C — Environmental
ParameterValue
Operating ambient temperature5...122 °F (-15...50 °C) (without derating) 122...140 °F (50...60 °C) (with derating factor)
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV930C11N4C — Approvals
ParameterValue
Certifications & markingCE
Standards complianceUL 508C IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
ATV930C11N4C — Communication
ParameterValue
Communication protocolsEtherNet/IP Modbus serial Modbus TCP

Product details

110 kW drive for asynchronous and synchronous motors

The ATV930C11N4C is a 110 kW normal duty / 90 kW heavy duty variable speed drive from the Altivar Process ATV900 family, designed for 3-phase 380-480 V supplies. It delivers 211 A continuous at 2.5 kHz switching in normal duty, and 173 A in heavy duty — the rating that governs the motor sizing for constant-torque loads like conveyors or extruders. This is the standard version without a built-in braking chopper. If the application needs dynamic braking for overhauling loads (cranes, centrifuges, vertical conveyors), an external braking resistor and chopper module must be added.

Current ratings and duty selection

At 2.5 kHz switching frequency, the drive delivers 211 A continuous in normal duty (110 kW typical motor) and 173 A in heavy duty (90 kW). Heavy duty is the spec to use for constant-torque or high-starting-torque applications — the drive's thermal capacity is sized to the HD current, not the ND figure. The switching frequency can be raised above 2.5 kHz, but the continuous output current must be derated per the drive's thermal model. At higher carrier frequencies, motor acoustic noise drops but the drive's IGBT junction temperature rises, reducing the available output.

Mounting, enclosure, and environmental limits

Wall-mount enclosure, IP21 / UL Type 1 — suitable for indoor, clean environments. The drive must be mounted vertically within ±10° for proper convective cooling. Forced air volume is 600 m³/h; the fan intake and exhaust need clearance per the installation manual. Rated for 1000 m altitude without derating. Above that, derate output current 1% per 100 m up to 4800 m. Ambient temperature range is not listed in this record, but the cooling air volume and IP21 enclosure suggest a standard 40-50 °C ambient ceiling — confirm the derating curve for the specific installation. Vibration resistance: 1.5 mm peak-to-peak at 2-13 Hz, 1 gn at 13-200 Hz per IEC 60068-2-6. Shock: 15 gn for 11 ms per IEC 60068-2-27. The drive can handle the mechanical environment of a typical motor control centre or panel on a concrete floor.

Communications, I/O, and option slots

Embedded communication ports support EtherNet/IP, Modbus serial, and Modbus TCP. The Ethernet port handles 10/100 Mbit with half/full duplex and autonegotiation. A serial port runs at 9600 or 19200 bps, 8-bit data with configurable parity. Three option slots (A, B, C) accept fieldbus modules (Profibus DP V1, PROFINET, DeviceNet, EtherCAT, CANopen, Ethernet Powerlink), I/O extension modules, encoder interface modules (digital 5/12 V, analog, resolver), and relay output modules. Slot A is typically used for the primary fieldbus; slots B and C for encoder feedback or additional I/O. Internal 24 V DC supply for digital inputs and STO (safe torque off) — 21-27 V DC. Separate 10.5 V DC reference for a 1-10 kΩ potentiometer. External 24 V DC supply (19-30 V) can also be used for digital inputs.

Standards, approvals, and grid compliance

Listed to UL 508C (power conversion equipment) and carries CE marking. Complies with IEC 61800-3 (EMC environment), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonic emissions), IEC 60721-3 (environmental classification), IEC 61508 (functional safety), and IEC 13849-1 (safety-related parts). Overvoltage category III, pollution degree 2. Integrated EMC filter meets conducted emission limits for the intended installation environment; an optional EMC plate is available for higher-performance filtering. Total harmonic current distortion (THDI) is <48% at full load per IEC 61000-3-12.

Frequently asked questions

What compliance documentation is available for the ATV930C11N4C?

The drive carries CE marking and is listed to UL 508C. It complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. The manufacturer provides the full declaration of conformity and installation manual with the unit.

How can I order the ATV930C11N4C or check availability?

Sourced to order against the BOM quantity through independent distribution.

MPN
ATV930C11N4C