Integrator note
It delivers 110.0 kW in normal duty and 90.0 kW in heavy duty, with a nominal output current of 211 A and continuous current of 211 A at 2.5 kHz normal duty or 173 A at 2.5 kHz heavy duty. Enclosure is IP21 / UL type 1, wall-mount, without a braking chopper — plan for an external braking resistor if your deceleration profile demands it.
Control wiring and options
Digital inputs and STO require an external 24 V DC supply (range 19...30 V). There's also an internal 24 V supply for the same circuits and 10.5 V DC for a reference potentiometer (1 to 10 kOhm). The control terminal accepts 0.5...1.5 mm² / AWG 20...16, while power and motor terminals handle 2 x 50...3 x 120 mm² / AWG 1/0...300 kcmil. Communication is via Ethernet IP/Modbus TCP (half/full duplex, autonegotiation, 10/100 Mbits). Slot A accepts communication modules for Profibus DP V1, PROFINET, DeviceNet, EtherCAT, CANopen, and Ethernet Powerlink.
Compliance is broad: CE marked, UL 508C, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. The embedded EMC filter is integrated; an EMC plate is optional. TAA compliant via COTS designation (BABA BAA). Ambient conditions: 5...95% relative humidity non-condensing, pollution degree 2, overvoltage category III, operating altitude up to 4800 m with 1% derating per 100 m above 1000 m.