Schneider Electric ATV930C22N4CUS — AC Drive (VFD) 480V

Schneider ATV930C22N4CUS VSD, 427A, 220 kW

MPNATV930C22N4CUS
Active

Schneider Electric Altivar Process ATV930C22N4CUS variable speed drive, 380-480 V 3-phase, 427 A nominal output, 220 kW normal duty / 160 kW heavy duty, IP21, UL Type 1.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV930C22N4CUS — Identification
ParameterValue
Product typeVariable speed drive
Product range / familyAltivar Process ATV900
ATV930C22N4CUS — Power & Output
ParameterValue
Motor power (kW)220.0 kW normal duty 160.0 kW heavy duty
Continuous output current302 A 2.5 kHz heavy duty 427 A 2.5 kHz normal duty
ATV930C22N4CUS — Input / Supply
ParameterValue
Rated supply voltage range380...480 V
Internal/auxiliary suppliesExternal supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm 500 V DC for 1 minute to earth
ATV930C22N4CUS — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated With EMC plate option
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
ATV930C22N4CUS — Mechanical & Cooling
ParameterValue
Degree of protection (IP)UL type 1
IP degree of protectionIP21
Acoustic noise level73 dB
Assembly / installation styleEnclosed
ATV930C22N4CUS — Environmental
ParameterValue
Operating ambient temperature14...104 °F (-10...40 °C) (without derating) 104...140 °F (40...60 °C) (with derating factor)
Operating altitude3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-13...158 °F (-25...70 °C)
Pollution degree2
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV930C22N4CUS — Approvals
ParameterValue
Certifications & markingCE
Standards complianceUL 508C IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
ATV930C22N4CUS — Communication
ParameterValue
Communication protocolsModbus serial EtherNet/IP Modbus TCP

Product details

Schneider ATV930C22N4CUS is an Altivar Process ATV900 drive for synchronous or asynchronous motors, rated 427 A continuous output at 2.5 kHz for normal duty (220 kW) and 302 A for heavy duty (160 kW) on a 380–480 V three-phase supply. It's a standard version without a braking chopper — if you need dynamic braking for vertical loads or high inertia, plan an external chopper module. Enclosed wall-mount, rated IP21 and UL Type 1, so it's for indoor dry locations; no washdown or dust-tight rating here.

Mount vertical +/-10°; the unit pulls 860 m³/h of cooling air, so keep grilles clear and allow side clearance for flow. Power terminals on line, motor, and DC bus accept 2 x 150 mm² or 2 x 350 kcmil — copper or aluminum lug compatible, but torque ratings aren't in this spec summary; confirm with the manual. Control wiring uses screw terminals 0.5–1.5 mm² (AWG 20–16). Digital inputs need an external 24 V DC supply (19–30 V). There's also an internal 10.5 V DC pot supply (1–10 kΩ) and internal 24 V DC for STO and digital inputs (21–27 V). Communication slots: one slot A for fieldbus modules (Profibus DP, PROFINET, EtherCAT, CANopen, Ethernet Powerlink, etc.), slots B and C for I/O or relay extensions. Onboard Ethernet IP/Modbus TCP with auto-negotiation.

CE marked, listed to UL 508C, and complies with IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonics), IEC 60721-3 (environmental), IEC 61508 and IEC 13849-1 (functional safety). Integrated EMC filter meets conducted emissions for most industrial environments; the optional EMC plate can tighten radiated performance if your install is sensitive.

Frequently asked questions

What are the key electrical ratings for this drive?

380–480 V three-phase input, 427 A nominal output at 2.5 kHz, supporting 220 kW normal duty or 160 kW heavy duty on asynchronous or synchronous motors.

What supply voltages are needed for control wiring?

Digital inputs require an external 24 V DC (19–30 V). There is also an internal 10.5 V DC supply for a 1–10 kΩ potentiometer, and internal 24 V DC (21–27 V) for STO and digital inputs.

What compliance certifications does it carry?

CE marked, UL 508C listed, and compliant with IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonics), IEC 60721-3, IEC 61508, and IEC 13849-1.

MPN