Skip to main content
Schneider Electric ATV930D30N4US — AC Drive (VFD) 480V

Schneider ATV930D30N4US Altivar Process VFD, 30 kW ND, 61.5

MPNATV930D30N4US
Active

Schneider Electric Altivar Process ATV900 series, ATV930D30N4US, 30 kW normal duty / 22 kW heavy duty variable speed drive, 61.5 A continuous output, 380-480 V 3-phase, IP21, UL Type 1, integrated braking chopper.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ATV930D30N4US — Identification
ParameterValue
Product typeVariable speed drive
Product range / familyAltivar Process ATV900
ATV930D30N4US — Power & Output
ParameterValue
Motor power (kW)30.0 kW normal duty 22.0 kW heavy duty
Continuous output current61.5 A 4 kHz normal duty 46.3 A 4 kHz heavy duty
ATV930D30N4US — Input / Supply
ParameterValue
Rated supply voltage range380...480 V
Internal/auxiliary suppliesExternal supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm 500 V DC for 1 minute to earth
ATV930D30N4US — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated With EMC plate option
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
ATV930D30N4US — Mechanical & Cooling
ParameterValue
Degree of protection (IP)UL type 1
IP degree of protectionIP21
Acoustic noise level71.5 dB
Assembly / installation styleEnclosed
ATV930D30N4US — Environmental
ParameterValue
Operating ambient temperature5...122 °F (-15...50 °C) (without derating) 122...140 °F (50...60 °C) (with derating factor)
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV930D30N4US — Approvals
ParameterValue
Certifications & markingCE
Standards complianceUL 508C IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
ATV930D30N4US — Communication
ParameterValue
Communication protocolsModbus serial EtherNet/IP Modbus TCP

Product details

The Schneider ATV930D30N4US is an Altivar Process ATV900 series variable speed drive rated for 30.0 kW normal duty and 22.0 kW heavy duty on a 380...480 V 3-phase supply. Continuous output current is 61.5 A at 4 kHz for normal duty, 46.3 A at 4 kHz for heavy duty. The drive includes an integrated braking chopper as standard, and the enclosure is rated IP21 / UL Type 1 for wall-mount installation.

Ratings and fit for the BOM line

The nominal output current is 61.5 A. The heavy-duty rating is 46.3 A at 4 kHz. Supply voltage is 380...480 V 3-phase. The integrated EMC filter meets IEC 61800-3 conducted emission limits. Control wiring is straightforward: digital inputs accept 24 V DC from an external supply (19...30 V), and there is an internal 10.5 V DC supply for a reference potentiometer (1 to 10 kOhm). The STO (Safe Torque Off) circuit uses a separate 24 V DC supply (21...27 V). Terminal sizes on the line, motor, and DC bus sides accept 25...50 mm² (AWG 4...AWG 1), which covers the cable needed for a 30 kW motor at 480 V.

Fieldbus and option slots

The drive ships with Ethernet IP / Modbus TCP on board, half/full duplex with auto-negotiation at 10/100 Mbits. Serial Modbus is also present at 9600 or 19200 bit/s, 8 bits, configurable parity. For other networks, slot A accepts a Profibus DP V1, PROFINET, DeviceNet, EtherCAT, or CANopen module; slot B handles encoder interfaces (digital 5/12 V, analog, or resolver); slot C takes relay or I/O extension modules. That means the same drive frame covers multiple plant-floor protocols without a hardware revision.

Mount the drive vertically within ±10 degrees. Operating altitude is 1000...4800 m with a 1 % current derating per 100 m above 1000 m. Ambient conditions: 5...95 % relative humidity without condensation, pollution degree 2. Vibration resistance is 1.5 mm peak-to-peak at 2...13 Hz and 1 gn at 13...200 Hz; shock resistance is 15 gn for 11 ms. The drive requires 240 m³/h of cooling air.

Frequently asked questions

What are the key electrical ratings for this drive?

It is rated for 30.0 kW normal duty / 22.0 kW heavy duty on a 380...480 V 3-phase supply, with a continuous output current of 61.5 A at 4 kHz normal duty and 46.3 A at 4 kHz heavy duty.

What communication protocols does it support?

It includes built-in Ethernet IP/Modbus TCP (10/100 Mbits, half/full duplex) and serial Modbus (9600/19200 bit/s). Optional slot A modules add Profibus DP V1, PROFINET, DeviceNet, EtherCAT, or CANopen.

What compliance documentation is available?

The drive is CE marked and complies with UL 508C, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. It is also TAA-compliant via COTS.

MPN