Specifications

ATV930D55N4 — Identification
ParameterValue
Product typeVariable speed drive
Product range / familyAltivar Process ATV900
ATV930D55N4 — Power & Output
ParameterValue
Motor power (kW)55.0 kW normal duty 45.0 kW heavy duty
Continuous output current106 A 2.5 kHz normal duty 88 A 2.5 kHz heavy duty
ATV930D55N4 — Input / Supply
ParameterValue
Rated supply voltage range380...480 V
Internal/auxiliary suppliesExternal supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm 500 V DC for 1 minute to earth
ATV930D55N4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated With EMC plate option
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
ATV930D55N4 — Mechanical & Cooling
ParameterValue
Degree of protection (IP)UL type 1
IP degree of protectionIP21
Acoustic noise level68.3 dB
Assembly / installation styleEnclosed
ATV930D55N4 — Environmental
ParameterValue
Operating ambient temperature5...122 °F (-15...50 °C) (without derating) 122...140 °F (50...60 °C) (with derating factor)
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV930D55N4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceUL 508C IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
ATV930D55N4 — Communication
ParameterValue
Communication protocolsEtherNet/IP Modbus TCP Modbus serial

Product details

Active production — 55 kW normal duty, 106 A continuous

The ATV930D55N4: Rated 55 kW normal duty and 45 kW heavy duty, it delivers 106 A continuous output at 2.5 kHz switching frequency — the heavy-duty figure governs applications like crushers and conveyors where the motor runs at or near full rated current continuously. The 380-480 V three-phase input matches standard 480 V plant distribution without a step-down transformer.

Compliance stack — UL 508C, IEC 61800-3, IEC 61508

Certified to UL 508C for North American power conversion equipment and IEC 61800-3 for adjustable-speed drive EMC — the integrated EMC filter covers conducted emissions for most industrial environments without an external add-on. Functional safety compliance to IEC 61508 and IEC 13849-1 supports SIL-rated safe torque off (STO) integration into safety circuits — the STO supply is a separate 24 V DC input (21-27 V), keeping the safety chain isolated from the control logic. THDI below 48 % from 80-100 % load meets IEC 61000-3-12 harmonic limits, avoiding the need for a line reactor on most utility feeds.

Built-in braking chopper and multi-protocol networking

The standard variant includes a braking chopper — for pump deceleration or conveyor stops, this handles regenerative energy without a separate brake module, saving panel space and wiring. EtherNet/IP, Modbus TCP, and Modbus serial are onboard; Slot A accepts Profibus DP, PROFINET, DeviceNet, EtherCAT, or CANopen option cards, so the drive fits into existing control architectures without a gateway. The adjustable PID regulator runs process loops (pressure, flow, level) directly in the drive — no external controller needed for single-loop applications.

Wall-mount enclosed design with IP21 / UL Type 1 protection — suitable for indoor, clean, non-washdown environments; the 68.3 dB noise level may require enclosure or remote mounting in quiet areas. Operating altitude up to 1000 m without derating; above that, derate output current 1 % per 100 m — a 1500 m installation loses 5 % of the rated current. Line and motor terminals accept 70-120 mm² (AWG 1/0-250 kcmil) — sized for the 106 A output without adapter lugs.

Frequently asked questions

How do I get current pricing and availability for ATV930D55N4?

Sourced and quoted to order through independent distribution.

MPN
ATV930D55N4