Skip to main content
Schneider Electric ATV930D55N4ZU — AC Drive (VFD) 480V

Schneider ATV930D55N4ZU Altivar Process Drive, 55 kW, 106 A

MPNATV930D55N4ZU
Active

Schneider Electric Altivar Process ATV900, variable speed drive, ATV930D55N4ZU, 55 kW normal duty / 45 kW heavy duty, 106 A, 380-480 V 3-phase, IP21, UL type 12.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ATV930D55N4ZU — Identification
ParameterValue
Product typeVariable speed drive
Product range / familyAltivar Process ATV900
ATV930D55N4ZU — Power & Output
ParameterValue
Motor power (kW)55.0 kW normal duty 45.0 kW heavy duty
Continuous output current106 A 2.5 kHz normal duty 88 A 2.5 kHz heavy duty
ATV930D55N4ZU — Input / Supply
ParameterValue
Rated supply voltage range380...480 V
Internal/auxiliary suppliesExternal supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm 500 V DC for 1 minute to earth
ATV930D55N4ZU — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated With EMC plate option
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
ATV930D55N4ZU — Mechanical & Cooling
ParameterValue
Degree of protection (IP)UL type 12
IP degree of protectionIP21
Acoustic noise level68.3 dB
Assembly / installation styleWith heat sink
ATV930D55N4ZU — Environmental
ParameterValue
Operating ambient temperature5...122 °F (-15...50 °C) (without derating) 122...140 °F (50...60 °C) (with derating factor)
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV930D55N4ZU — Approvals
ParameterValue
Certifications & markingCE
Standards complianceUL 508C IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
ATV930D55N4ZU — Communication
ParameterValue
Communication protocolsEtherNet/IP Modbus TCP Modbus serial

Product details

The Schneider ATV930D55N4ZU is an Altivar Process ATV900 variable speed drive sized for 55 kW normal duty or 45 kW heavy duty on a 380-480 V 3-phase supply. It delivers 106 A continuous at 2.5 kHz in normal duty, 88 A in heavy duty. Built-in braking chopper, integrated EMC filter, and a full set of fieldbus options (EtherNet/IP, Modbus TCP, Modbus serial, plus slot-based Profibus DP, PROFINET, DeviceNet, EtherCAT, CANopen, and Ethernet Powerlink).

The 55 kW normal duty / 45 kW heavy duty split is the key sizing decision. Normal duty covers variable-torque loads like fans and pumps; heavy duty handles constant-torque or high-starting-torque applications such as conveyors or extruders. The 106 A nominal output current is the headline number, but the continuous output current at switching frequency tells the real story: 106 A at 2.5 kHz for normal duty, 88 A at 2.5 kHz for heavy duty. If your application needs a higher carrier frequency for quieter motor operation, expect derating beyond those figures. The drive accepts 380-480 V 3-phase input and includes an integrated EMC filter (with an optional EMC plate for stricter emissions). The IP21 enclosure and UL type 12 rating mean it's protected against dust and dripping water — fine for a clean control room, but not for washdown areas.

Cabinet-mount only, vertical +/-10°, with a heat sink. Requires 295 m³/h of cooling air. Control wiring uses screw terminals accepting 0.5-1.5 mm² (AWG 20-16). Communication defaults to EtherNet/IP and Modbus TCP on the built-in port, with Modbus serial as a fallback. For other fieldbuses, slot A accepts Profibus DP, PROFINET, DeviceNet, EtherCAT, or CANopen modules. Slots A, B, and C also accept digital/analog I/O or relay extension modules; slot B can host encoder interfaces (digital 5/12 V, analog, or resolver). The PID regulator is adjustable onboard, so closed-loop control for pressure, flow, or level doesn't require an external controller.

Carries CE marking and complies with UL 508C, IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonic), IEC 60721-3 (environmental), IEC 61508, and IEC 13849-1 (functional safety). The integrated STO (Safe Torque Off) supply is 24 V DC, 21-27 V — separate from the digital input supply (24 V DC, 19-30 V). The internal 10.5 V DC reference for a 1-10 kΩ potentiometer is available for local speed reference without an external power supply.

Frequently asked questions

What is the listed phase for this drive?

3-phase input.

What is the supply voltage range?

380-480 V AC, 3-phase. The control logic requires external 24 V DC (19-30 V) for digital inputs, and a separate 24 V DC (21-27 V) for STO.

What compliance documentation does this drive carry?

CE marked, UL 508C listed, and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1.

MPN
ATV930D55N4ZU