Specifications

ATV950D75N4E — Identification
ParameterValue
Product typeVariable speed drive
Product range / familyAltivar Process ATV900
ATV950D75N4E — Power & Output
ParameterValue
Motor power (kW)75.0 kW for normal duty 55.0 kW for heavy duty
Continuous output current145 A at 2.5 kHz for normal duty 106 A at 2.5 kHz for heavy duty
ATV950D75N4E — Input / Supply
ParameterValue
Rated supply voltage range380...480 V
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), 1 MOhm 500 V DC for 1 minute to earth
ATV950D75N4E — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated With EMC plate option
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
ATV950D75N4E — Mechanical & Cooling
ParameterValue
Degree of protection (IP)UL type 1
IP degree of protectionIP55
Acoustic noise level69.9 dB
Assembly / installation styleEnclosed
ATV950D75N4E — Environmental
ParameterValue
Operating ambient temperature-15...40 °C (without derating) 40...50 °C (with derating factor)
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV950D75N4E — Approvals
ParameterValue
Certifications & markingCE
Standards complianceUL 508C IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
ATV950D75N4E — Communication
ParameterValue
Communication protocolsModbus TCP EtherNet/IP Modbus serial

Product details

Drive rating and duty selection

The ATV950D75N4E is a 75.0 kW normal-duty, 55.0 kW heavy-duty variable speed drive from the Altivar Process ATV900 family, sized for 380...480 V three-phase supply. Continuous output current is 145 A at 2.5 kHz for normal duty, 106 A at 2.5 kHz for heavy duty — the heavy-duty figure governs when the motor is sized for constant-torque loads like conveyors or extruders; the normal-duty figure applies to variable-torque loads such as centrifugal pumps and fans. The drive includes a load break switch and a braking chopper as standard, so no external contactor or braking resistor wiring is needed for the chopper circuit itself.

Environmental and installation constraints

IP55 enclosure and UL Type 1 rating permit wall-mount installation in washdown areas or dusty industrial environments without an additional cabinet, though the 69.9 dB noise level should be considered for operator-occupied zones. Operating altitude is 1000 m nominal, derating 1 % per 100 m above that up to 4800 m. Vibration resistance is 1.5 mm peak-to-peak at 2...13 Hz and 1 gn at 13...200 Hz per IEC 60068-2-6; shock resistance is 15 gn for 11 ms per IEC 60068-2-27. The drive must be mounted vertical ±10°.

Control wiring and auxiliary supplies

Control connections use screw terminals accepting 0.5...1.5 mm². The drive provides an internal 24 V DC supply (21...27 V) for digital inputs and STO, plus a separate 10.5 V DC ±5 % supply for a 1 to 10 kOhm reference potentiometer. External digital inputs can also be powered from a 24 V DC (19...30 V) source. Insulation resistance is tested at 1 MOhm, 500 V DC for one minute to earth. Line-side and motor terminals accept up to 95 mm² and 95...120 mm² respectively; DC bus terminals accept 70...120 mm².

Communication and expandability

Native communication ports support Modbus TCP, EtherNet/IP, and Modbus serial at selectable rates from 9600 bit/s to 100 Mbit/s. Slot A accepts fieldbus option modules for Profibus DP V1, PROFINET, DeviceNet, EtherCAT, CANopen (daisy-chain RJ45, SUB-D 9, or screw terminals), or Ethernet Powerlink. Slots A, B, and C accept digital and analog I/O extension modules or output relay extension modules. Slot B also accepts 5/12 V digital encoder, analog encoder, or resolver encoder interface modules. The regulation loop includes an adjustable PID controller. Data format is 8 bits with configurable odd, even, or no parity; exchange mode is half duplex, full duplex, or autonegotiation.

Standards, EMC, and functional safety

The drive carries CE marking and complies with UL 508C, IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonic emissions), IEC 60721-3 (environmental), IEC 61508, and IEC 13849-1 (functional safety). The integrated EMC filter with optional EMC plate meets conducted emission limits for industrial environments. Maximum THDI is below 48 % from 80...100 % load per IEC 61000-3-12. EMC immunity includes electrostatic discharge level 3, radiated RF level 3, fast transient level 4, surge level 3, and conducted RF level 3 per the respective IEC 61000-4-X standards. Chemical pollution resistance class 3C3 and dust pollution resistance class 3S3 per IEC 60721-3-3. The drive is suitable for both synchronous and asynchronous motors in industrial process applications.

Frequently asked questions

Where can I buy the ATV950D75N4E and get a price?

The ATV950D75N4E is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — both are confirmed at quote time.

What is the closest alternative to the ATV950D75N4E in the Altivar Process family?

Within the ATV900 series, the closest peer is the ATV950D63N4E (63 kW normal duty, 55 kW heavy duty, 124 A output). The ATV950D75N4E steps up to 75 kW normal duty and 145 A output for the same 380...480 V supply. Both share the same IP55 enclosure, integrated braking chopper, and option module slots — the difference is the continuous current rating, which governs the motor frame size the drive can support.

What compliance documentation does the ATV950D75N4E carry?

CE marking is on the nameplate. Standards compliance includes UL 508C, IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. RoHS and REACH documentation is standard for the Altivar Process range.

MPN