Skip to main content
Schneider Electric ATV980C80Q4X1 — AC Drive (VFD) 480V

Schneider ATV980C80Q4X1 Altivar Process ATV980, 800-630kW, 4

MPNATV980C80Q4X1
Active

Schneider Electric Altivar Process ATV900 series, ATV980 regenerative drive, ATV980C80Q4X1, 800 to 630kW, 380-415 V three-phase, IP23, CE.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV980C80Q4X1 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV980
Product range / familyAltivar Process ATV900

Input / Supply

ATV980C80Q4X1 — Input / Supply
ParameterValue
Rated supply voltage range380...415 V - 10...6 %
Network number of phases3 phases

Mechanical & Cooling

ATV980C80Q4X1 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP23 conforming to IEC 61800-5-1
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure compact version

Environmental

ATV980C80Q4X1 — Environmental
ParameterValue
Operating ambient temperature-10...0 °C without derating (with option enclosure heating) 0...40 °C without derating 40...50 °C with derating factor
Operating altitude1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-25...70 °C
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 3...20 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10...200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3 1.5 mm peak to peak (f= 3...10 Hz) conforming to IEC 60068-2-6

Approvals

ATV980C80Q4X1 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 60204-1 IEC 61800-5-1 IEC 61800-2 IEC 61800-3

Protection & EMC

ATV980C80Q4X1 — Protection & EMC
ParameterValue
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6

Communication

ATV980C80Q4X1 — Communication
ParameterValue
Communication protocolsEtherNet/IP Modbus serial Modbus TCP

Product details

Drive selection memo — regenerative system for 400 V class

The ATV980C80Q4X1 is a variable speed drive from the Altivar Process ATV900 series, specifically the ATV980 regenerative variant, delivering 800 to 630 kW on a 380...415 V three-phase supply. This is a floor-standing compact enclosure, pre-configured with the line choke, dv/dt filter choke, main switch, and graphical operating panel mounted in the door — it arrives as a near-complete drive cabinet, not a bare chassis. Rated for asynchronous and synchronous motors, it handles the regenerative energy from overhauling loads (cranes, conveyors on a decline, test stands) by feeding it back to the line rather than dumping it as heat across a braking resistor. The total harmonic current distortion stays under 5 % at full load, compliant with IEEE 519, which keeps the plant's distribution clean without needing a separate active filter.

The 380...415 V -10...6 % supply range covers the standard European 400 V class with enough headroom for weak grids. IP23 means the enclosure is drip-proof but not washdown-rated — suitable for a clean electrical room or a controlled industrial hall, not for direct spray-down areas. Forced convection cooling requires clearance around the cabinet for airflow; the operating position is vertical ±10 degrees. The vibration and shock ratings (1.5 mm peak-to-peak at 3...20 Hz, 4 gn for 11 ms) matter for applications like marine or mobile plant equipment where the drive sees continuous low-frequency vibration. Altitude derating starts at 1000 m — 1 % per 100 m for all earthing systems (TT, TN, IT) up to 3800 m, and continues to 4800 m with the same rate. If the drive is going into a high-altitude installation, factor that into the motor current rating.

Frequently asked questions

What compliance standards does the ATV980C80Q4X1 meet?

It is CE marked and complies with IEC 60204-1, IEC 61800-5-1, IEC 61800-2, and IEC 61800-3. It also meets IEEE 519 for total harmonic current distortion below 5 % at full load.

What is the supply voltage and power range for this drive?

It operates on a 380...415 V three-phase supply, -10...6 %, and covers the 800 to 630 kW power range. The drive is a regenerative system, feeding braking energy back to the line.

What is the enclosure rating and cooling method?

IP23 per IEC 61800-5-1 with forced convection cooling. It is a floor-standing compact enclosure suitable for indoor electrical rooms, not washdown environments.