ATV9A0C11Q4 - Schneider Electric
MPNATV9A0C11Q4
Active
Variable speed drive, Altivar Process ATV900, APM, single 400 V, 110 kW
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Product type | Variable speed drive |
| Device short name | ATV9A0 |
| Product range / family | Altivar Process ATV900 |
| Parameter | Value |
|---|---|
| Motor power (kW) | 110.0 kW at 400 V normal duty 90.0 kW at 400 V heavy duty |
| Continuous output current | 211.0 A at 2.5 kHz normal duty 173.0 A at 2.5 kHz heavy duty |
| Max. transient current | 253.2 A during 60 s (normal duty) 259.5 A during 60 s (heavy duty) |
| Apparent power | 137.0 kVA at 400 V normal duty 116.0 kVA at 400 V heavy duty |
| Parameter | Value |
|---|---|
| Rated supply voltage range | 400 V - 15...10 % |
| Input line current | 198.0 A at 400 V (normal duty) 167.0 A at 400 V (heavy duty) |
| Network number of phases | 3 phases |
| Internal/auxiliary supplies | External supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), 1 MOhm at 500 V DC, 1 min, earth |
| Parameter | Value |
|---|---|
| Output frequency range | 0.1...599 Hz |
| Asynchronous motor control modes | Optimized torque mode Variable torque standard Constant torque standard |
| Synchronous motor control modes | Permanent magnet motor Synchronous reluctance motor |
| Parameter | Value |
|---|---|
| Integrated EMC filter class | Integrated with 300 m conforming to IEC 61800-3 category C3 |
| Protection functions | Thermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive |
| EMC immunity tests | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Prospective short-circuit current (Isc) | 50 kA |
| Parameter | Value |
|---|---|
| IP degree of protection | IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529 |
| Acoustic noise level | 69 dB conforming to 86/188/EEC |
| Cooling method | Forced convection |
| Parameter | Value |
|---|---|
| Operating ambient temperature | -10...40 °C without derating 40...50 °C with derating factor |
| Operating altitude | 0...4800 m with current derating above 1000m |
| Relative humidity | 5...95 % without condensation conforming to IEC 60068-2-3 |
| Storage / transport temperature | -40...70 °C |
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| Vibration resistance | 1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6 |
| Parameter | Value |
|---|---|
| Certifications & marking | CE |
| Standards compliance | IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 |
| Parameter | Value |
|---|---|
| Communication protocols | EtherNet/IP Modbus serial Modbus TCP |
MPN