Schneider Electric ATV9A0C13Q4 — AC Drive (VFD) 480V

Schneider ATV9A0C13Q4 Altivar Process ATV900, 132 kW

MPNATV9A0C13Q4
Active

Schneider Electric Altivar Process ATV900, modular variable speed drive, ATV9A0C13Q4, 132 kW at 400 V normal duty, 110 kW heavy duty, IP00.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV9A0C13Q4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV9A0
Product range / familyAltivar Process ATV900

Power & Output

ATV9A0C13Q4 — Power & Output
ParameterValue
Motor power (kW)132.0 kW at 400 V normal duty 110.0 kW at 400 V heavy duty
Continuous output current250.0 A at 2.5 kHz normal duty 211.0 A at 2.5 kHz heavy duty
Max. transient current300.0 A during 60 s (normal duty) 316.5 A during 60 s (heavy duty)
Apparent power161.0 kVA at 400 V normal duty 137.0 kVA at 400 V heavy duty

Input / Supply

ATV9A0C13Q4 — Input / Supply
ParameterValue
Rated supply voltage range400 V - 15...10 %
Input line current233.0 A at 400 V (normal duty) 198.0 A at 400 V (heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), 1 MOhm at 500 V DC, 1 min, earth

Control & Performance

ATV9A0C13Q4 — Control & Performance
ParameterValue
Output frequency range0.1...599 Hz
Asynchronous motor control modesOptimized torque mode Variable torque standard Constant torque standard
Synchronous motor control modesPermanent magnet motor Synchronous reluctance motor

Protection & EMC

ATV9A0C13Q4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated with 300 m conforming to IEC 61800-3 category C3
Protection functionsThermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA

Mechanical & Cooling

ATV9A0C13Q4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529
Acoustic noise level69 dB conforming to 86/188/EEC
Cooling methodForced convection

Environmental

ATV9A0C13Q4 — Environmental
ParameterValue
Operating ambient temperature-10...40 °C without derating 40...50 °C with derating factor
Operating altitude0...4800 m with current derating above 1000m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

Approvals

ATV9A0C13Q4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Communication

ATV9A0C13Q4 — Communication
ParameterValue
Communication protocolsEtherNet/IP Modbus serial Modbus TCP

Product details

The Schneider ATV9A0C13Q4 is an Altivar Process ATV900 modular drive rated for 132 kW at 400 V in normal duty and 110 kW in heavy duty, drawing 233 A and 198 A line current respectively.

Duty ratings and motor match

Normal duty delivers 161 kVA apparent power for a 132 kW asynchronous or synchronous motor; heavy duty drops to 137 kVA for 110 kW. The switching frequency is adjustable from 2.5 to 8 kHz with derating above the default — useful for matching motor cable length or acoustic noise targets.

Safety and compliance

The drive carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, and IEC 60721-3. The integrated EMC filter meets category C3 for 300 m cable runs.

Fieldbus and I/O expansion

Three option card slots (A, B, C) accept Profibus DP V1, PROFINET, DeviceNet, EtherCAT, CANopen, or digital/analog I/O and relay extension modules. Slot B also supports encoder interfaces (digital 5/12 V, analog, resolver). The control block has dual RJ45 for Ethernet IP/Modbus TCP and one RJ45 for Modbus serial (RS-485, RTU, 1-247 addresses).

Supply and control wiring

Digital inputs and STO are powered by an internal 24 V DC supply (21...27 V). An external 24 V DC (19...30 V) can also feed the digital inputs. A 10.5 V DC reference supply is provided for a 1 to 10 kOhm potentiometer. Line-side connection is via screw terminals; motor connection uses M10 x 2 bars.

Cabinet-mount design with IP00 protection (requires IP21 or IP54 enclosure integration). Rated for pollution degree 2, operating altitude up to 4800 m with derating above 1000 m, and 5-95% relative humidity without condensation. Vibration resistance: 1.5 mm peak-to-peak at 2-13 Hz, 0.5 gn at 13-200 Hz. Shock resistance: 7 gn for 11 ms.

Frequently asked questions

What are the key power ratings for the ATV9A0C13Q4?

It is rated 132 kW at 400 V normal duty (233 A line current, 161 kVA) and 110 kW at 400 V heavy duty (198 A line current, 137 kVA).

What safety functions does the ATV9A0C13Q4 include?

It includes Safe Torque Off (STO) rated at SIL 3, along with thermal protection, motor phase break detection, overcurrent, short-circuit, and DC bus overvoltage protection.

How do I source the ATV9A0C13Q4?

This is a current-production unit sourced to order against an RFQ. Submit a request for a firm price and lead time.

MPN
ATV9A0C13Q4