Skip to main content
Schneider Electric ATV9A0C13S6

Schneider ATV9A0C13S6 Altivar Process ATV900, 150 HP at 600

MPN ATV9A0C13S6
Active

Schneider Electric Altivar Process ATV900, modular VFD, ATV9A0C13S6, 150 hp at 600 V normal duty, 131 A line current.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV9A0C13S6 specifications
ParameterValue
Connector type2 RJ45 Ethernet IP/Modbus TCP on terminal 1 RJ45 Modbus serial on terminal
Main product or component typeVariable speed drive
Current131.0 A 600 V normal duty) 112.0 A 600 V heavy duty)
Horsepower150.0 hp at 600 V normal duty 125.0 hp at 600 V heavy duty
Frequency50...60 Hz +/- 5 %
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature-40...158 °F (-40...70 °C)
Pollution degreePollution degree 2
Data format8 bits, configurable odd, even or no parity Modbus serial
Operating temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor

Product details

The Schneider Electric ATV9A0C13S6 is an Altivar Process ATV900 modular drive rated for 150 hp at 600 V normal duty and 125 hp at 600 V heavy duty, drawing 131 A and 112 A line current respectively. It handles both synchronous and asynchronous motors and includes an integrated EMC filter compliant with IEC 61800-3 category C3 for cable runs up to 300 m.

Supply architecture is split: digital inputs and STO need a 24 V DC supply in the 21–27 V range, while the reference potentiometer gets its own 10.5 V DC ±5 % rail. That means you cannot share a single 24 V bus between the control logic and the pot wiper without a separate regulator — the 10.5 V rail is dedicated.

Safety and connectivity

STO (Safe Torque Off) is built in at SIL 3, so you can wire a safety relay or light curtain directly without an external safety contactor. The drive also monitors motor phase break, output phase-to-earth faults, DC bus overvoltage, and line supply phase loss — all listed in the protection set. Three option slots (A, B, C) accept communication modules for Profibus DP V1, PROFINET, DeviceNet, CANopen, EtherCAT, plus I/O and encoder interface modules. Slot A is the typical fieldbus slot; slots B and C handle encoder feedback or relay extensions. The base unit includes dual RJ45 Ethernet IP/Modbus TCP ports and one RJ45 Modbus serial port, so you can talk to the PLC and a local HMI without an extra card.

MPN
ATV9A0C13S6