Schneider Electric ATV9A0C13S6 — AC Drive (VFD) 600V

Schneider ATV9A0C13S6 Altivar Process ATV900, 150 HP at 600

MPNATV9A0C13S6
Active

Schneider Electric Altivar Process ATV900, modular VFD, ATV9A0C13S6, 150 hp at 600 V normal duty, 131 A line current.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV9A0C13S6 — Identification
ParameterValue
Product range / seriesAltivar Process ATV900
Device short name / model codeATV9A0
Product / component typeVariable speed drive
ATV9A0C13S6 — Electrical (input)
ParameterValue
Rated supply voltage600 V - 10...15 %
Network phases3 phases
Supply frequency50...60 Hz +/- 5 %
Line (input) current131.0 A 600 V normal duty) 112.0 A 600 V heavy duty)
Prospective line short-circuit current (Isc)50 kA
EMC filterIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Max. input current THD (THDi)<48 % from 80...100 % of load
ATV9A0C13S6 — Output / Performance
ParameterValue
Apparent power136.0 kVA at 600 V normal duty 116.0 kVA at 600 V heavy duty
Continuous output current145.0 A at 2.5 kHz normal duty 125.0 A at 2.5 kHz heavy duty
Switching (PWM) frequency2...4.9 kHz adjustable with derating factor
ATV9A0C13S6 — Communication
ParameterValue
Communication protocolsEtherNet/IP Modbus serial Modbus TCP
Address range1...247 Modbus serial
Data format8 bits, configurable odd, even or no parity Modbus serial
ATV9A0C13S6 — Mechanical
ParameterValue
Mounting modeCabinet mount
Terminal / wiring connectionControl removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars
Product destination / compatibilitySynchronous motors Asynchronous motors
ATV9A0C13S6 — Environmental
ParameterValue
Degree of protection (IEC, IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP rating (with kit options)IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Storage temperature-40...158 °F (-40...70 °C)
Operating altitude (with derating)0...2000 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Pollution degree2 IEC 61800-5-1
Environmental resistance classesChemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
Shock resistance4 gn 11 ms IEC 60068-2-27
Acoustic noise level69 dB 86/188/EEC
ATV9A0C13S6 — Approvals & Compliance
ParameterValue
StandardsIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1
Agency markings / approvalsCE

Product details

The Schneider Electric ATV9A0C13S6 is an Altivar Process ATV900 modular drive rated for 150 hp at 600 V normal duty and 125 hp at 600 V heavy duty, drawing 131 A and 112 A line current respectively. It handles both synchronous and asynchronous motors and includes an integrated EMC filter compliant with IEC 61800-3 category C3 for cable runs up to 300 m.

Supply architecture is split: digital inputs and STO need a 24 V DC supply in the 21–27 V range, while the reference potentiometer gets its own 10.5 V DC ±5 % rail. That means you cannot share a single 24 V bus between the control logic and the pot wiper without a separate regulator — the 10.5 V rail is dedicated.

Safety and connectivity

STO (Safe Torque Off) is built in at SIL 3, so you can wire a safety relay or light curtain directly without an external safety contactor. The drive also monitors motor phase break, output phase-to-earth faults, DC bus overvoltage, and line supply phase loss — all listed in the protection set. Three option slots (A, B, C) accept communication modules for Profibus DP V1, PROFINET, DeviceNet, CANopen, EtherCAT, plus I/O and encoder interface modules. Slot A is the typical fieldbus slot; slots B and C handle encoder feedback or relay extensions. The base unit includes dual RJ45 Ethernet IP/Modbus TCP ports and one RJ45 Modbus serial port, so you can talk to the PLC and a local HMI without an extra card.

Frequently asked questions

What are the key electrical ratings for the ATV9A0C13S6?

It is rated 150 hp at 600 V normal duty and 125 hp at 600 V heavy duty, with line currents of 131 A and 112 A respectively. Apparent power is 136 kVA at 600 V normal duty.

What safety functions does this drive include?

It includes Safe Torque Off (STO) rated SIL 3, plus thermal protection, overcurrent, short-circuit, phase loss, and DC bus overvoltage monitoring on both motor and drive sides.

What fieldbus options are available for the ATV9A0C13S6?

The base unit has dual Ethernet IP/Modbus TCP ports and one Modbus serial port. Option slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT modules. Slots B and C accept I/O extension, relay, or encoder interface modules.

MPN