Skip to main content
Schneider Electric ATV9A0C71T4 — AC Drive (VFD) 480V

Schneider ATV9A0C71T4 Altivar Process ATV900 Drive, 1000 HP

MPNATV9A0C71T4
Active

Schneider Electric Altivar Process ATV900, modular VFD, ATV9A0C71T4, 1000 hp normal duty / 800 hp heavy duty at 480 V, IP00, forced convection cooling.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV9A0C71T4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV9A0
Product range / familyAltivar Process ATV900

Input / Supply

ATV9A0C71T4 — Input / Supply
ParameterValue
Rated supply voltage range480 V - 15...10 %
Input line current1044.0 A 480 V normal duty) 846.0 A 480 V heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm at 500 V DC, 1 min, earth

Power & Output

ATV9A0C71T4 — Power & Output
ParameterValue
Continuous output current1260.0 A at 2.5 kHz normal duty 1020.0 A at 2.5 kHz heavy duty
Max. transient current1512.0 A 60 s normal duty) 1530.0 A 60 s heavy duty)
Apparent power868.0 kVA at 480 V normal duty 703.0 kVA at 480 V heavy duty

Control & Performance

ATV9A0C71T4 — Control & Performance
ParameterValue
Output frequency range0.1...599 Hz
Asynchronous motor control modesOptimized torque mode Variable torque standard Constant torque standard
Synchronous motor control modesPermanent magnet motor Synchronous reluctance motor

Protection & EMC

ATV9A0C71T4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA

Mechanical & Cooling

ATV9A0C71T4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Acoustic noise level74 dB 86/188/EEC
Cooling methodForced convection

Environmental

ATV9A0C71T4 — Environmental
ParameterValue
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Operating altitude0...4800 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2 IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

Approvals

ATV9A0C71T4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Communication

ATV9A0C71T4 — Communication
ParameterValue
Communication protocolsEtherNet/IP Modbus serial Modbus TCP

Product details

The Schneider ATV9A0C71T4 is an Altivar Process ATV900 modular variable frequency drive rated for 1000 hp normal duty or 800 hp heavy duty at 480 V, with a corresponding line current of 1044 A normal duty and 846 A heavy duty. It handles both synchronous and asynchronous motors, with an adjustable switching frequency from 2 to 8 kHz (derated above 2.5 kHz).

Control supply and wiring

The control block requires an external 24 V DC supply (19...30 V) for digital inputs, plus an internal 24 V DC (21...27 V) supply for digital inputs and STO. A separate 10.5 V DC ±5 % reference is provided for a 1 to 10 kΩ potentiometer. The control wiring uses removable screw terminals accepting 0.5...1.5 mm² (AWG 20...16).

Communications and option slots

Dual RJ45 ports on the control block support Ethernet IP/Modbus TCP at 10/100 Mbit/s, plus one RJ45 for Modbus serial (RS-485, 2-wire) at 4.8 to 38.4 kbit/s. Three option card slots (A, B, C) accept Profibus DP V1, PROFINET, DeviceNet, EtherCAT, CANopen, digital/analog I/O extension, relay extension, and encoder interfaces (digital 5/12 V, analog, or resolver).

Safety and compliance

The drive complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, and carries CE marking. The integrated EMC filter meets IEC 61800-3 category C3 for 300 m cable runs. Pollution degree 2, vibration and shock per IEC 60068-2-6 and IEC 60068-2-27.

Frequently asked questions

What are the key power ratings for the ATV9A0C71T4?

It is rated for 1000 hp normal duty / 800 hp heavy duty at 480 V, with line currents of 1044 A normal duty and 846 A heavy duty.

What compliance markings and standards does the ATV9A0C71T4 meet?

CE marking; complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1.

MPN
ATV9A0C71T4