Skip to main content
Schneider Electric ATV9B0C13N6 — AC Drives (VFD)

Schneider ATV9B0C13N6 Altivar Process ATV900, 90 kW at 500 V

MPNATV9B0C13N6
Active

Schneider Altivar Process ATV900, modular drive, ATV9B0C13N6, 90 kW at 500 V normal duty, 75 kW heavy duty, integrated EMC filter C3.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV9B0C13N6 — Identification
ParameterValue
Product rangeAltivar Process ATV900
Product / component typeVariable speed drive
ATV9B0C13N6 — Power & Current
ParameterValue
Continuous output current145.0 A at 2.5 kHz normal duty 125.0 A at 2.5 kHz heavy duty 145.0 A at 2.5 kHz normal duty regenerative mode 125.0 A at 2.5 kHz heavy duty regenerative mode
ATV9B0C13N6 — Control & Communication
ParameterValue
Switching frequency2.5 kHz
Synchronous motor control profilePermanent magnet motor Synchronous reluctance motor
Communication protocols / portsEtherNet/IP Modbus serial Modbus TCP
Acceleration / deceleration rampsLinear adjustable separately from 0.01...9999 s
Product destinationSynchronous motors Asynchronous motors
ATV9B0C13N6 — Protection & Environmental
ParameterValue
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
Degree of protection (IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
ATV9B0C13N6 — Electrical
ParameterValue
Supply frequency50...60 Hz +/- 5 %
Network number of phases3 phases

Product details

The Schneider ATV9B0C13N6 is an Altivar Process ATV900 modular drive rated for 90 kW at 500 V normal duty and 75 kW at 500 V heavy duty, with corresponding line currents of 117 A and 98 A. It carries an integrated EMC filter compliant with IEC 61800-3 category C3 for cable runs up to 300 m, and includes STO (safe torque off) rated SIL 3.

The 90 kW normal-duty rating covers constant-torque applications like conveyors and pumps. The 75 kW heavy-duty rating applies to variable-torque loads with higher peak demands, such as crushers or extruders. The integrated EMC filter at category C3 means the drive is suitable for industrial environments with a dedicated transformer — no external filter needed for the first 300 m of motor cable. Three option-card slots (A, B, C) accept fieldbus modules (PROFIBUS DP V1, PROFINET, EtherCAT, CANopen, DeviceNet) and I/O or relay extensions. Slot B also accepts encoder interface modules for closed-loop control.

Cabinet-mount design. Power connections are screw terminals on the line side and M10 bars on the motor side. Forced-convection cooling; derate above 1000 m altitude. The drive is IP00, intended for IP21 or IP54 cabinet integration.

CE marked. Standards include IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonics), IEC 60721-3 (environmental), IEC 61508 and IEC 13849-1 (functional safety). Prospective line Isc rated at 50 kA. Pollution degree 2.

Frequently asked questions

What are the key power ratings of the ATV9B0C13N6?

It is rated for 90 kW at 500 V normal duty and 75 kW at 500 V heavy duty, with line currents of 117 A and 98 A respectively.

What safety functions does the ATV9B0C13N6 include?

It includes STO (safe torque off) rated SIL 3.

What fieldbus options are available for the ATV9B0C13N6?

Slot A accepts PROFIBUS DP V1, PROFINET, EtherCAT, CANopen, and DeviceNet modules. Slots A, B, and C also accept digital/analog I/O and relay extension modules. Slot B accepts encoder interface modules.

MPN
ATV9B0C13N6