Schneider Electric ATV9B0C13Q4 — AC Drive (VFD) 480V

Schneider ATV9B0C13Q4 Altivar Process ATV900, 132 kW, 208 A

MPNATV9B0C13Q4
Active

Schneider Electric Altivar Process ATV900, ATV9B0C13Q4, 132 kW at 400 V normal duty, 208 A line current, modular cabinet mount.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV9B0C13Q4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV9B0
Product range / familyAltivar Process ATV900

Power & Output

ATV9B0C13Q4 — Power & Output
ParameterValue
Motor power (kW)132.0 kW at 400 V normal duty 110.0 kW at 400 V heavy duty 132.0 kW at 400 V normal duty regenerative mode 110.0 kW at 400 V heavy duty regenerative mode
Continuous output current250.0 A at 2.5 kHz normal duty 211.0 A at 2.5 kHz heavy duty 250.0 A at 2.5 kHz normal duty regenerative mode 211.0 A at 2.5 kHz heavy duty regenerative mode
Max. transient current300.0 A during 60 s (normal duty) 316.5 A during 60 s (heavy duty) 300.0 A during 60 s regenerative mode (normal duty) 316.5 A during 60 s regenerative mode (heavy duty)
Apparent power144.0 kVA at 400 V normal duty 121.0 kVA at 400 V heavy duty 120.4 kVA at 400 V normal duty regenerative mode 99.8 kVA at 400 V heavy duty regenerative mode

Input / Supply

ATV9B0C13Q4 — Input / Supply
ParameterValue
Rated supply voltage range400 V - 15...10 %
Input line current208.0 A at 400 V (normal duty) 174.0 A at 400 V (heavy duty) 173.8 A at 400 V regenerative mode (normal duty) 144.1 A at 400 V regenerative mode (heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), 1 MOhm at 500 V DC, 1 min, earth

Control & Performance

ATV9B0C13Q4 — Control & Performance
ParameterValue
Output frequency range0.1...599 Hz
Asynchronous motor control modesOptimized torque mode Variable torque standard Constant torque standard
Synchronous motor control modesPermanent magnet motor Synchronous reluctance motor

Protection & EMC

ATV9B0C13Q4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated with 300 m conforming to IEC 61800-3 category C3
Protection functionsThermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6

Mechanical & Cooling

ATV9B0C13Q4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529
Acoustic noise level70 dB conforming to 86/188/EEC
Cooling methodForced convection

Environmental

ATV9B0C13Q4 — Environmental
ParameterValue
Operating ambient temperature-5...40 °C without derating 40...50 °C with derating factor
Operating altitude0...4800 m with current derating above 1000m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

Approvals

ATV9B0C13Q4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Communication

ATV9B0C13Q4 — Communication
ParameterValue
Communication protocolsEtherNet/IP Modbus serial Modbus TCP

Product details

The ATV9B0C13Q4: The drive carries separate normal-duty and heavy-duty curves. Normal duty delivers 132 kW / 208 A / 144 kVA; heavy duty delivers 110 kW / 174 A / 121 kVA. Regenerative-mode ratings are also specified: 132 kW / 173.8 A / 120.4 kVA normal duty, 110 kW / 144.1 A / 99.8 kVA heavy duty. The switching frequency is adjustable 2 to 8 kHz with derating above 2.5 kHz.

Safety and compliance

Safe Torque Off (STO) rated SIL 3 is integrated. The drive complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. The integrated EMC filter meets category C3 per IEC 61800-3 for cable runs up to 300 m. Pollution degree 2 per IEC 61800-5-1.

Supply and control

Digital inputs require an external 24 V DC supply (19...30 V). An internal 10.5 V DC supply powers a reference potentiometer (1 to 10 kOhm). The STO and digital input internal supply is 24 V DC (21...27 V). Insulation resistance is 1 MOhm at 500 V DC for 1 minute to earth.

Fieldbus and option slots

The drive includes 2 RJ45 ports for Ethernet IP/Modbus TCP and 1 RJ45 for Modbus serial (RS-485, 2-wire, RTU frame, 4.8 to 38.4 kbit/s). Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT communication modules. Slot B accepts digital/analog I/O extension, output relay, or encoder interface modules (digital 5/12 V, analog, or resolver). Slot C also accepts I/O or relay extensions.

Frequently asked questions

What are the motor power ratings for the ATV9B0C13Q4?

The drive is rated 132 kW at 400 V normal duty and 110 kW at 400 V heavy duty.

What safety functions does the ATV9B0C13Q4 include?

It includes Safe Torque Off (STO) rated SIL 3.

What fieldbus options are available for the ATV9B0C13Q4?

It has built-in Ethernet IP/Modbus TCP and Modbus serial. Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT modules.

What is the line current at 400 V for the ATV9B0C13Q4?

208 A at normal duty, 174 A at heavy duty.

MPN
ATV9B0C13Q4