Skip to main content
Schneider Electric ATV9B0C16N6 — AC Drives (VFD)

Schneider ATV9B0C16N6 Altivar Process ATV900 Drive, 110 kW

MPNATV9B0C16N6
Active

Schneider Electric Altivar Process ATV900, ATV9B0C16N6, 110 kW at 500 V normal duty, 141 A line current, STO SIL 3, integrated EMC filter C3.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV9B0C16N6 — Identification
ParameterValue
Product rangeAltivar Process ATV900
Product / component typeVariable speed drive
ATV9B0C16N6 — Power & Current
ParameterValue
Continuous output current175.0 A at 2.5 kHz normal duty 145.0 A at 2.5 kHz heavy duty 175.0 A at 2.5 kHz normal duty regenerative mode 145.0 A at 2.5 kHz heavy duty regenerative mode
ATV9B0C16N6 — Control & Communication
ParameterValue
Switching frequency2.5 kHz
Synchronous motor control profilePermanent magnet motor Synchronous reluctance motor
Communication protocols / portsEtherNet/IP Modbus serial Modbus TCP
Acceleration / deceleration rampsLinear adjustable separately from 0.01...9999 s
Product destinationSynchronous motors Asynchronous motors
ATV9B0C16N6 — Protection & Environmental
ParameterValue
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
Degree of protection (IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
ATV9B0C16N6 — Electrical
ParameterValue
Supply frequency50...60 Hz +/- 5 %
Network number of phases3 phases

Product details

The Schneider ATV9B0C16N6 is an Altivar Process ATV900 modular drive rated for 110 kW at 500 V normal duty and 90 kW at 500 V heavy duty. Line current sits at 141 A normal duty, 117 A heavy duty, with regenerative mode ratings at 114 A and 92 A respectively. The supply architecture splits: digital inputs and STO take 24 V DC (21...27 V), while the reference potentiometer gets a separate 10.5 V DC ±5 % rail — keep those supplies isolated in the panel design.

Safety and compliance

The drive carries CE marking and complies with IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonics), IEC 60721-3 (environmental), and IEC 61508. Integrated EMC filter meets category C3 for 300 m cable runs — no external filter needed for most industrial installations.

Fieldbus and I/O options

Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), or EtherCAT communication modules. Slots A, B, and C take digital/analog I/O extension or output relay modules. Slot B also supports 5/12 V digital encoder, analog encoder, or resolver interface modules. Native Ethernet IP/Modbus TCP on dual RJ45 ports plus one RJ45 for Modbus serial at 4.8 to 38.4 kbit/s.

Power quality and thermal

Total harmonic current distortion (THDI) stays under 5% at full load per IEEE 519. Switching frequency is adjustable from 2 to 4.9 kHz with derating. Forced convection cooling; IP00 rating for cabinet integration into IP21 or IP54 enclosures.

Frequently asked questions

What safety functions does the ATV9B0C16N6 support?

It supports STO (safe torque off) rated SIL 3.

What fieldbus options are available for this drive?

Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), or EtherCAT communication modules.

What is the motor power rating at 500 V?

110 kW at 500 V normal duty, 90 kW at 500 V heavy duty.

What EMC filter is integrated?

Integrated EMC filter meets IEC 61800-3 category C3 for 300 m cable runs.

MPN
ATV9B0C16N6