Schneider Electric ATV9B0C25Q6 — AC Drive (VFD) 600V

Schneider ATV9B0C25Q6 Altivar Process ATV900, 250 kW at 690

MPNATV9B0C25Q6
Active

Schneider Electric Altivar Process ATV900, ATV9B0C25Q6, 250 kW at 690 V normal duty, 228 A line current, modular cabinet-mount drive.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV9B0C25Q6 — Identification
ParameterValue
Product range / seriesAltivar Process ATV900
Device short name / model codeATV9B0
Product / component typeVariable speed drive
ATV9B0C25Q6 — Electrical (input)
ParameterValue
Rated supply voltage690 V - 10...15 %
Network phases3 phases
Supply frequency50...60 Hz +/- 5 %
Line (input) current228.0 A 690 V normal duty) 183.0 A 690 V heavy duty) 191.0 A 690 V regenerative mode normal duty) 152.0 A 690 V regenerative mode heavy duty)
Prospective line short-circuit current (Isc)50 kA
EMC filterIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Max. input current THD (THDi)<5 % full load IEEE 519
ATV9B0C25Q6 — Output / Performance
ParameterValue
Apparent power273.0 kVA at 690 V normal duty 219.0 kVA at 690 V heavy duty 228.0 kVA at 690 V normal duty regenerative mode 182.0 kVA at 690 V heavy duty regenerative mode
Continuous output current275.0 A at 2.5 kHz normal duty 215.0 A at 2.5 kHz heavy duty 275.0 A at 2.5 kHz normal duty regenerative mode 215.0 A at 2.5 kHz heavy duty regenerative mode
Switching (PWM) frequency2...4.9 kHz adjustable with derating factor
ATV9B0C25Q6 — Communication
ParameterValue
Communication protocolsEtherNet/IP Modbus serial Modbus TCP
Address range1...247 Modbus serial
Data format8 bits, configurable odd, even or no parity Modbus serial
ATV9B0C25Q6 — Mechanical
ParameterValue
Mounting modeCabinet mount
Terminal / wiring connectionControl removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars
Product destination / compatibilitySynchronous motors Asynchronous motors
ATV9B0C25Q6 — Environmental
ParameterValue
Degree of protection (IEC, IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP rating (with kit options)IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Operating ambient temperature23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Storage temperature-40...158 °F (-40...70 °C)
Operating altitude (with derating)0...2000 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Pollution degree2 IEC 61800-5-1
Environmental resistance classesChemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
Shock resistance4 gn 11 ms IEC 60068-2-27
Acoustic noise level73 dB 86/188/EEC
ATV9B0C25Q6 — Approvals & Compliance
ParameterValue
StandardsIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
Agency markings / approvalsCE

Product details

Drive selection memo for a 250 kW motor at 690 V

The ATV9B0C25Q6 is a Schneider Altivar Process ATV900 drive sized for a 250 kW asynchronous or synchronous motor on a 690 V line, normal duty. Line current draws 228 A at 690 V normal duty; heavy duty knocks that to 200 kW and 183 A. Apparent power runs 273 kVA normal duty, 219 kVA heavy. The integrated EMC filter meets IEC 61800-3 category C3 for 300 m cable runs. Safe torque off (STO) is built in at SIL 3, so you can skip an external safety relay for the drive stop.

Fieldbus and I/O expansion slots

This modular drive ships with a control unit, power module, front cover, and mechanical mounting kit. Slot A accepts communication modules for Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), or EtherCAT. Slots A, B, and C also accept digital/analog I/O extension or output relay modules. Slot B can take a 5/12 V digital encoder interface, analog encoder, or resolver interface. The control terminal uses removable screw terminals 0.5…1.5 mm².

Frequently asked questions

What are the key power ratings for the ATV9B0C25Q6?

Rated 250 kW at 690 V normal duty, 200 kW heavy duty. Line current 228 A normal duty, 183 A heavy duty. Apparent power 273 kVA normal duty, 219 kVA heavy duty.

What safety functions does the ATV9B0C25Q6 include?

Built-in Safe Torque Off (STO) rated SIL 3.

What fieldbus options are available for the ATV9B0C25Q6?

Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), or EtherCAT communication modules.

MPN