Skip to main content
Schneider Electric ATV9B0C56T4 — AC Drive (VFD) 480V

Schneider ATV9B0C56T4 Altivar Process ATV900, 800 hp at 480

MPNATV9B0C56T4
Active

Schneider Electric Altivar Process ATV900, ATV9B0C56T4, 800 hp at 480 V normal duty, 650 hp heavy duty, cabinet mount, modular version.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV9B0C56T4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV9B0
Product range / familyAltivar Process ATV900
ATV9B0C56T4 — Input / Supply
ParameterValue
Rated supply voltage range480 V
Input line current771.0 A 480 V normal duty) 626.0 A 480 V heavy duty) 668.8 A 480 V regenerative mode normal duty) 543.4 A 480 V regenerative mode heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm at 500 V DC, 1 min, earth
ATV9B0C56T4 — Power & Output
ParameterValue
Continuous output current1020.0 A at 2.5 kHz normal duty 830.0 A at 2.5 kHz heavy duty 1020.0 A at 2.5 kHz normal duty regenerative mode 830.0 A at 2.5 kHz heavy duty regenerative mode
Max. transient current1224.0 A 60 s normal duty) 1245.0 A 60 s heavy duty) 1224.0 A 60 s regenerative mode normal duty) 1245.0 A 60 s regenerative mode heavy duty)
Apparent power641.0 kVA at 480 V normal duty 520.0 kVA at 480 V heavy duty 556.0 kVA at 480 V normal duty regenerative mode 451.7 kVA at 480 V heavy duty regenerative mode
ATV9B0C56T4 — Control & Performance
ParameterValue
Output frequency range0.1...599 Hz
Asynchronous motor control modesOptimized torque mode Variable torque standard Constant torque standard
Synchronous motor control modesPermanent magnet motor Synchronous reluctance motor
ATV9B0C56T4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
ATV9B0C56T4 — Mechanical & Cooling
ParameterValue
Degree of protection (IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Acoustic noise level77 dB 86/188/EEC
Cooling methodForced convection
ATV9B0C56T4 — Environmental
ParameterValue
Operating ambient temperature23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Operating altitude0...4800 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2 IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV9B0C56T4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1
ATV9B0C56T4 — Communication
ParameterValue
Communication protocolsEtherNet/IP Modbus serial Modbus TCP

Product details

The Schneider ATV9B0C56T4 is an Altivar Process ATV900 variable frequency drive in the modular cabinet-mount format. It's rated for 800 hp at 480 V normal duty and 650 hp at 480 V heavy duty, with corresponding line currents of 771 A and 626 A. This is the current-production variant — no end-of-life notice on it.

Supply and control architecture

The drive needs an external 24 V DC supply (19...30 V) for the digital inputs. It also generates an internal 10.5 V DC reference for a 1 to 10 kOhm potentiometer, and a separate 24 V DC (21...27 V) rail for the digital inputs and STO safety circuit. Insulation resistance is 1 MOhm at 500 V DC for one minute to earth.

Motor and duty flexibility

Handles both asynchronous and synchronous motors. The switching frequency is adjustable from 2 to 8 kHz, with derating above 2.5 kHz. Apparent power at 480 V normal duty is 641 kVA; heavy duty drops to 520 kVA. Regenerative mode ratings are also specified: 556 kVA normal duty, 451.7 kVA heavy duty.

Safety and compliance

Integrated STO (Safe Torque Off) rated SIL 3. The drive carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and UL 61800-5-1. The built-in EMC filter meets IEC 61800-3 category C3 for cable runs up to 300 m. Pollution degree 2 per IEC 61800-5-1.

Fieldbus and I/O expansion

Comes with two RJ45 ports for Ethernet IP/Modbus TCP and one RJ45 for Modbus serial. Transmission rates are 10/100 Mbit/s on the Ethernet side and 4.8 to 38.4 kbit/s on Modbus serial (RTU, 2-wire RS-485, 1...247 addresses). Option card slots A, B, and C accept communication modules for Profibus DP V1, PROFINET, DeviceNet, CANopen (daisy chain RJ45, SUB-D 9, or screw terminals), and EtherCAT. I/O expansion and encoder interface modules also fit these slots.

Cabinet mount, forced convection cooling. Operating altitude up to 4800 m with derating above 1000 m. Ambient conditions: 5...95 % relative humidity non-condensing, vibration 1.5 mm peak-to-peak at 2...13 Hz and 0.5 gn at 13...200 Hz, shock 4 gn for 11 ms. IP00 rating for integration into IP21 or IP54 cabinets; also UL Type 1 and Type 12 when cabinet-integrated.

Sourcing note

This is a current-production drive.

Frequently asked questions

What motors does this drive support?

It is designed for both asynchronous (induction) and synchronous motors.

What safety function does it include?

Integrated Safe Torque Off (STO) rated SIL 3.

What communication protocols are available via option cards?

Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), and EtherCAT modules.

MPN