Schneider Electric ATV9B0C80N6 — AC Drives (VFD)

Schneider ATV9B0C80N6 Altivar Process ATV900, 560 kW at 500

MPNATV9B0C80N6
Active

Schneider Electric ATV9B0C80N6, Altivar Process ATV900, modular drive, 560 kW at 500 V normal duty, 701 A line current.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV9B0C80N6 — Identification
ParameterValue
Product rangeAltivar Process ATV900
Product / component typeVariable speed drive
ATV9B0C80N6 — Power & Current
ParameterValue
Continuous output current830.0 A at 2.5 kHz normal duty 650.0 A at 2.5 kHz heavy duty 650.0 A at 2.5 kHz normal duty regenerative mode 520.0 A at 2.5 kHz heavy duty regenerative mode
ATV9B0C80N6 — Control & Communication
ParameterValue
Switching frequency2.5 kHz
Synchronous motor control profilePermanent magnet motor Synchronous reluctance motor
Communication protocols / portsEtherNet/IP Modbus serial Modbus TCP
Acceleration / deceleration rampsLinear adjustable separately from 0.01...9999 s
Product destinationSynchronous motors Asynchronous motors
ATV9B0C80N6 — Protection & Environmental
ParameterValue
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
Degree of protection (IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
ATV9B0C80N6 — Electrical
ParameterValue
Supply frequency50...60 Hz +/- 5 %
Network number of phases3 phases

Product details

The ATV9B0C80N6: Built-in EMC filter meets IEC 61800-3 category C3 for 300 m cable runs. Control power comes from an external 24 V DC supply (19...30 V) for digital inputs, plus a dedicated 24 V DC (21...27 V) rail for STO and digital inputs. A 10.5 V DC reference supply is available for a 1 to 10 kΩ potentiometer.

Fieldbus and I/O expansion

The drive has three option card slots (A, B, C). Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), or EtherCAT. Slots A/B/C can host digital/analog I/O extension modules or output relay modules. Slot B also supports 5/12 V digital encoder, analog encoder, or resolver interface modules. Built-in Ethernet IP/Modbus TCP on two RJ45 ports, plus a separate RJ45 for Modbus serial (RS-485 2-wire, RTU, 4.8 to 38.4 kbit/s). Addressing range 1...247 on Modbus serial.

Frequently asked questions

What are the motor power ratings for the ATV9B0C80N6?

560 kW at 500 V normal duty, 450 kW at 500 V heavy duty, 450 kW at 500 V normal duty regenerative mode, and 355 kW at 500 V heavy duty regenerative mode.

What safety functions does the ATV9B0C80N6 support?

STO (Safe Torque Off) rated SIL 3 per IEC 61508 and IEC 13849-1.

What fieldbus options are available for the ATV9B0C80N6?

Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), or EtherCAT. Built-in Ethernet IP/Modbus TCP and Modbus serial are standard.

What is the line current at 500 V normal duty?

701 A at 500 V normal duty, 564 A at 500 V heavy duty.

MPN
ATV9B0C80N6