Skip to main content
Schneider Electric ATV9B0C80Q6 — AC Drive (VFD) 600V

Schneider ATV9B0C80Q6 Altivar Process ATV900 Drive, 800 kW

MPNATV9B0C80Q6
Active

Schneider Electric Altivar Process ATV900, modular variable speed drive, ATV9B0C80Q6, 800 kW at 690 V normal duty, 630 kW heavy duty, integrated EMC filter, STO SIL 3.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV9B0C80Q6 — Identification
ParameterValue
Product range / seriesAltivar Process ATV900
Device short name / model codeATV9B0
Product / component typeVariable speed drive
ATV9B0C80Q6 — Electrical (input)
ParameterValue
Rated supply voltage690 V - 10...15 %
Network phases3 phases
Supply frequency50...60 Hz +/- 5 %
Line (input) current718.0 A 690 V normal duty) 569.0 A 690 V heavy duty) 487.0 A 690 V regenerative mode normal duty) 384.0 A 690 V regenerative mode heavy duty)
Prospective line short-circuit current (Isc)50 kA
EMC filterIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Max. input current THD (THDi)<5 % full load IEEE 519
ATV9B0C80Q6 — Output / Performance
ParameterValue
Apparent power859.0 kVA at 690 V normal duty 680.0 kVA at 690 V heavy duty 582.0 kVA at 690 V normal duty regenerative mode 459.0 kVA at 690 V heavy duty regenerative mode
Continuous output current830.0 A at 2.5 kHz normal duty 650.0 A at 2.5 kHz heavy duty 650.0 A at 2.5 kHz normal duty regenerative mode 520.0 A at 2.5 kHz heavy duty regenerative mode
Switching (PWM) frequency2...4.9 kHz adjustable with derating factor
ATV9B0C80Q6 — Communication
ParameterValue
Communication protocolsEtherNet/IP Modbus serial Modbus TCP
Address range1...247 Modbus serial
Data format8 bits, configurable odd, even or no parity Modbus serial
ATV9B0C80Q6 — Mechanical
ParameterValue
Mounting modeCabinet mount
Terminal / wiring connectionControl removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars
Product destination / compatibilitySynchronous motors Asynchronous motors
ATV9B0C80Q6 — Environmental
ParameterValue
Degree of protection (IEC, IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP rating (with kit options)IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Operating ambient temperature23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Storage temperature-40...158 °F (-40...70 °C)
Operating altitude (with derating)0...2000 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Pollution degree2 IEC 61800-5-1
Environmental resistance classesChemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
Shock resistance4 gn 11 ms IEC 60068-2-27
Acoustic noise level77 dB 86/188/EEC
ATV9B0C80Q6 — Approvals & Compliance
ParameterValue
StandardsIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
Agency markings / approvalsCE

Product details

The Schneider ATV9B0C80Q6 is an Altivar Process ATV900 modular drive rated for 800 kW at 690 V normal duty and 630 kW at 690 V heavy duty, with line currents of 718 A and 569 A respectively. It handles synchronous and asynchronous motors and includes an integrated EMC filter compliant with IEC 61800-3 category C3 for cable runs up to 300 m.

If your motor nameplate is 630 kW and the load profile includes sustained overloads, this drive handles it without derating. The regenerative-mode ratings (630 kW normal, 500 kW heavy) apply when the drive must return energy to the line — common in hoisting or centrifuge duty. Switching frequency is adjustable from 2 to 4.9 kHz with derating. At the default 2 kHz you get full rated current; pushing to 4.9 kHz reduces output current — factor that into your motor's audible noise and cable-length budget. Safe Torque Off (STO) is built in at SIL 3 per IEC 61508, so you can eliminate an external safety relay for many applications. The drive also provides thermal protection, overcurrent, phase loss, and overspeed monitoring on both the motor and drive sides.

Integration notes

Line-side and motor connections are M10 bus bars. The drive has two RJ45 Ethernet ports for IP/Modbus TCP and one RJ45 for Modbus serial (RS-485, 2-wire).

Frequently asked questions

What are the key power ratings for this drive?

800 kW at 690 V normal duty, 630 kW at 690 V heavy duty. For regenerative applications, 630 kW normal duty and 500 kW heavy duty at 690 V.

What safety functions are included?

Safe Torque Off (STO) rated SIL 3 is integrated. The drive also provides thermal protection, overcurrent, phase loss, and overspeed monitoring for both motor and drive.

What communication options are available?

Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT modules. Additional slots support I/O extension and encoder interface modules. Built-in Ethernet IP/Modbus TCP (2 ports) and Modbus serial RS-485.

How do I source this drive?

This is a current-production item sourced to order. Submit an RFQ for lead time and pricing; no minimum order quantity beyond the unit.

MPN
ATV9B0C80Q6