Skip to main content
Schneider Electric ATV9B0C80T4 — AC Drive (VFD) 480V

Schneider ATV9B0C80T4 Altivar Process ATV900, 1100 HP at 480

MPNATV9B0C80T4
Active

Schneider Electric Altivar Process ATV900, modular VFD, 1100 HP at 480 V normal duty, 900 HP heavy duty, STO SIL 3, integrated EMC filter C3, IP00 for cabinet integration.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV9B0C80T4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV9B0
Product range / familyAltivar Process ATV900

Input / Supply

ATV9B0C80T4 — Input / Supply
ParameterValue
Rated supply voltage range480 V
Input line current1049.0 A 480 V normal duty) 862.0 A 480 V heavy duty) 929.1 A 480 V regenerative mode normal duty) 756.3 A 480 V regenerative mode heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), 1 MOhm at 500 V DC, 1 min, earth

Power & Output

ATV9B0C80T4 — Power & Output
ParameterValue
Continuous output current1420.0 A at 2.5 kHz normal duty 1140.0 A at 2.5 kHz heavy duty 1420.0 A at 2.5 kHz normal duty regenerative mode 1140.0 A at 2.5 kHz heavy duty regenerative mode
Max. transient current1704.0 A 60 s normal duty) 1710.0 A 60 s heavy duty) 1704.0 A 60 s regenerative mode normal duty) 1710.0 A 60 s regenerative mode heavy duty)
Apparent power872.0 kVA at 480 V normal duty 717.0 kVA at 480 V heavy duty 772.5 kVA at 480 V normal duty regenerative mode 628.8 kVA at 480 V heavy duty regenerative mode

Control & Performance

ATV9B0C80T4 — Control & Performance
ParameterValue
Output frequency range0.1...599 Hz
Asynchronous motor control modesOptimized torque mode Variable torque standard Constant torque standard
Synchronous motor control modesPermanent magnet motor Synchronous reluctance motor

Protection & EMC

ATV9B0C80T4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6

Mechanical & Cooling

ATV9B0C80T4 — Mechanical & Cooling
ParameterValue
Degree of protection (IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Acoustic noise level78 dB 86/188/EEC
Cooling methodForced convection

Environmental

ATV9B0C80T4 — Environmental
ParameterValue
Operating ambient temperature23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Operating altitude0...4800 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2 IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

Approvals

ATV9B0C80T4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1

Communication

ATV9B0C80T4 — Communication
ParameterValue
Communication protocolsEtherNet/IP Modbus serial Modbus TCP

Product details

The ATV9B0C80T4 is a modular Altivar Process ATV900 drive sized for 1100 HP at 480 V normal duty, 900 HP at 480 V heavy duty. Line current runs 1049 A normal duty, 862 A heavy duty at 480 V; regenerative mode pulls 929.1 A normal duty, 756.3 A heavy duty. The internal supply rails are separate: 24 V DC (19…30 V) for digital inputs, 10.5 V DC ±5 % for a reference potentiometer (1 to 10 kΩ), and a dedicated 24 V DC (21…27 V) rail for digital inputs and STO.

Safety and compliance

The drive carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, UL 61800-5-1. Integrated EMC filter meets IEC 61800-3 category C3 for 300 m cable runs. Pollution degree 2 per IEC 61800-5-1.

Fieldbus and I/O expansion

Slot A accepts communication modules for Profibus DP V1, PROFINET, DeviceNet, CANopen (daisy chain RJ45, SUB-D 9, or screw terminals), and EtherCAT. Slot A/B/C accept digital/analog I/O extension modules and output relay extension modules. Slot B accepts 5/12 V digital encoder, analog encoder, and resolver encoder interface modules. Dual RJ45 ports for Ethernet IP/Modbus TCP; one RJ45 for Modbus serial. Modbus serial runs 2-wire RS-485 at 4.8, 9.6, 19.2, 38.4 kbit/s, RTU frame, 1…247 addresses.

Frequently asked questions

What are the key ratings for this drive?

Motor power is 1100 HP at 480 V normal duty, 900 HP at 480 V heavy duty. Line current is 1049 A normal duty, 862 A heavy duty at 480 V. Apparent power is 872 kVA normal duty, 717 kVA heavy duty at 480 V.

What fieldbus options are available?

Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), and EtherCAT. Dual RJ45 ports for Ethernet IP/Modbus TCP; one RJ45 for Modbus serial.

What compliance standards does it meet?

CE marked. Complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, UL 61800-5-1.

MPN
ATV9B0C80T4