Skip to main content
Schneider Electric ATV9B0M10Q6 — AC Drive (VFD) 600V

Schneider Electric ATV9B0M10Q6 AC Drive, 1000 kW at 690 V

MPNATV9B0M10Q6
Active

Schneider Electric Altivar Process ATV900 series, ATV9B0M10Q6 AC Drive (VFD) 600V, modular version, 1000 kW at 690 V normal duty, 800 kW heavy duty, IP00 for cabinet integration.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV9B0M10Q6 — Identification
ParameterValue
Product range / seriesAltivar Process ATV900
Device short name / model codeATV9B0
Product / component typeVariable speed drive
ATV9B0M10Q6 — Electrical (input)
ParameterValue
Rated supply voltage690 V - 10...15 %
Network phases3 phases
Supply frequency50...60 Hz +/- 5 %
Line (input) current898.0 A 690 V normal duty) 718.0 A 690 V heavy duty) 621.0 A 690 V regenerative mode normal duty) 487.0 A 690 V regenerative mode heavy duty)
Prospective line short-circuit current (Isc)50 kA
EMC filterIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Max. input current THD (THDi)<5 % full load IEEE 519
ATV9B0M10Q6 — Output / Performance
ParameterValue
Apparent power1073.0 kVA at 690 V normal duty 859.0 kVA at 690 V heavy duty 743.0 kVA at 690 V normal duty regenerative mode 582.0 kVA at 690 V heavy duty regenerative mode
Continuous output current1030.0 A at 2.5 kHz normal duty 830.0 A at 2.5 kHz heavy duty 830.0 A at 2.5 kHz normal duty regenerative mode 650.0 A at 2.5 kHz heavy duty regenerative mode
Switching (PWM) frequency2...4.9 kHz adjustable with derating factor
ATV9B0M10Q6 — Communication
ParameterValue
Communication protocolsEtherNet/IP Modbus serial Modbus TCP
Address range1...247 Modbus serial
Data format8 bits, configurable odd, even or no parity Modbus serial
ATV9B0M10Q6 — Mechanical
ParameterValue
Mounting modeCabinet mount
Terminal / wiring connectionControl removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars
Product destination / compatibilitySynchronous motors Asynchronous motors
ATV9B0M10Q6 — Environmental
ParameterValue
Degree of protection (IEC, IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP rating (with kit options)IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Operating ambient temperature23...104 °F (-5...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Storage temperature-40...158 °F (-40...70 °C)
Operating altitude (with derating)0...2000 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Pollution degree2 IEC 61800-5-1
Environmental resistance classesChemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
Shock resistance4 gn 11 ms IEC 60068-2-27
Acoustic noise level78 dB 86/188/EEC
ATV9B0M10Q6 — Approvals & Compliance
ParameterValue
StandardsIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
Agency markings / approvalsCE

Product details

Motor power and duty ratings

The ATV9B0M10Q6: Rated 1000 kW at 690 V in normal duty and 800 kW at 690 V in heavy duty, with corresponding apparent power of 1073 kVA and 859 kVA respectively. Line current at 690 V is 898 A normal duty, 718 A heavy duty. The regenerative mode ratings drop to 621 A and 487 A respectively — factor this in if the application includes a braking resistor or regenerative supply.

Safety and compliance

Integrated EMC filter meets IEC 61800-3 category C3 for 300 m cable runs — suitable for industrial environments with a dedicated transformer or TN-S supply. The filter is built in; no external EMC box needed for most installations. CE marked, with standards compliance to IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. Prospective line Isc is 50 kA — coordinate the upstream breaker accordingly.

Fieldbus and I/O options

Three option card slots (A, B, C) accept communication modules for Profibus DP V1, PROFINET, DeviceNet, CANopen, EtherCAT, plus digital/analog I/O extension and encoder interfaces. Slot A handles the main fieldbus; slot B can take a resolver or encoder feedback card for closed-loop motor control. Built-in dual RJ45 Ethernet IP/Modbus TCP ports plus a separate RJ45 Modbus serial port. The Modbus serial runs at 4.8 to 38.4 kbit/s RTU; Ethernet ports are 10/100 Mbit/s. The drive ships as a Modbus TCP slave by default.

Frequently asked questions

How do I get current pricing and availability for ATV9B0M10Q6?

Submit an RFQ through this listing. The drive is sourced to order from authorized distribution; pricing and lead time are confirmed at quote time based on your quantity and delivery window.

What is ATV9B0M10Q6's listed supply for digital inputs and STO?

The drive provides an external supply for digital inputs at 24 V DC (19...30 V), an internal supply for a reference potentiometer at 10.5 V DC ±5%, and an internal supply for digital inputs and STO at 24 V DC (21...27 V). Insulation resistance is 1 MOhm at 500 V DC for 1 minute.

What compliance documentation does Schneider Electric provide for ATV9B0M10Q6?

The drive is CE marked and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. The integrated EMC filter meets category C3 per IEC 61800-3.

MPN