Schneider Electric C063H360FM

Schneider Electric C063H360FM ComPacT NS 630A 3P MCCB, 85 kA

MPN C063H360FM
Active

Schneider Electric ComPacT NS new generation, C063H360FM, 3P fixed MCCB, 630 A, MicroLogic 6.0 electronic trip unit, H breaking capacity (70 kA at 415 V AC), manually operated, IP40, IK07.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C063H360FM key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Poles3P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront

All specifications

C063H360FM additional specifications
ParameterValue
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width210 mm
Height327 mm
Electrical life cycles2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C063H360FM is a 3-pole fixed-mount ComPacT NS new generation MCCB rated 630 A at 50 °C with a MicroLogic 6.0 electronic trip unit. The trip unit provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground-fault) protection — the G function is built into the trip unit logic, though the breaker ships without earth-leakage relay hardware (without). Breaking capacity is the headline: 85 kA Icu at 240 V AC, 70 kA at 415 V, 65 kA at 440 V, 50 kA at 500/525 V, and 42 kA at 690 V. For a 630 A main breaker on a 2000 kVA transformer at 415 V, that 70 kA covers the prospective fault current without cascading upstream. The breaker is manually operated (no motor mechanism), fixed-mounted to a backplate, with front-front connection (line and load both front). Connection pitch is 70 mm. IP40 enclosure protection and IK07 impact resistance — suitable for indoor panel installation where occasional tool contact is expected, not washdown.

Standards compliance: EN/IEC 60947-2 (Category B), suitability for isolation per the same standard.

Durability and deployment context

Mechanical durability is 10,000 cycles; electrical durability varies with load: 2000 cycles at 690 V at full In, 4000 cycles at 690 V at In/2, 5000 cycles at 440 V at In, 6000 cycles at 440 V at In/2. For a main breaker that operates infrequently (once per shift or less), that is ample. For a switching duty application (frequent load disconnect), the electrical endurance at 440 V In/2 (6000 cycles) is the limiting figure. Thermal memory is 20 minutes — after a trip, the MicroLogic 6.0 remembers the thermal state for 20 minutes, so a reclose before that window sees a shorter time-to-trip on the next overload. This matters for motor starting or inrush-heavy loads where successive starts could nuisance-trip without the memory reset. Operating altitude: 0–2000 m no derating; 2000–5000 m with derating. Relative humidity 0–95%. Power losses are 10 W at rated current — negligible for panel thermal budgeting.

MPN
C063H360FM