Skip to main content
Schneider Electric C063H460FM

Schneider Electric C063H460FM ComPacT NS 630A 4P MCCB, 70kA

MPN C063H460FM
Active

Schneider Electric ComPacT NS new generation, C063H460FM, 4P MCCB, 630 A at 50 °C, MicroLogic 6.0 electronic trip unit, 70 kA Icu at 415 V AC, fixed mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C063H460FM key specifications
ParameterValue
Control typeManually operated
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500/525 V AC 50/60 Hz conforming to IEC 60947-2 42 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Poles4P
Utilization categoryCategory B
IP ratingIP40
Terminal pitch70 mm
Connection surface topFront
Connection surface bottomFront

All specifications

C063H460FM additional specifications
ParameterValue
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947
Depth147 mm
Width280 mm
Height327 mm
Electrical life cycles2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2
Mechanical life cycles10000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

630 A, 4-pole MCCB with MicroLogic 6.0 LSI protection

It carries a MicroLogic 6.0 electronic trip unit providing LSI protection — long-time (L) for overload, short-time (S) for short-time short-circuit, and instantaneous (I) for high-fault clearing. The H breaking capacity code delivers 70 kA Icu at 380/415 V AC, 50/60 Hz per IEC 60947-2, making it suitable for distribution switchboards where high fault current and selectivity are required. Rated 630 A at 50 °C, this breaker sits in the ComPacT NS630b...1600 new generation family, used for main or feeder protection in LV distribution panels. The 4P configuration with neutral left handles three-phase plus neutral loads without a separate neutral disconnect.

The H-rated frame gives 85 kA Icu at 240 V, 70 kA at 415 V, 65 kA at 440 V, and 42 kA at 690 V AC. For a 630 A main breaker on a 415 V system, 70 kA Icu provides solid short-circuit withstand for most industrial service-entrance applications — enough headroom for coordination with downstream 25–50 kA rated feeders. Category B utilization (IEC 60947-2) means it is designed for selectivity, not just cable protection.

Fixed mount on a backplate, 327 mm high × 280 mm wide × 147 mm deep. Front-side connection both top and bottom — no rear-access requirement.

Trip unit and diagnostics

MicroLogic 6.0 is fully electronic, with 20-minute thermal memory for accurate overload replay after a trip. Four red LEDs indicate fault type (long-time, short-time, instantaneous, ground fault) and one yellow LED signals overload pre-alarm — useful for field troubleshooting without plugging in a handheld. No earth-leakage protection built in; add a Vigi module externally if ground-fault protection is needed.

MPN