Schneider Electric C063H460FM — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C063H460FM ComPacT NS 630A 4P MCCB, 70kA

MPNC063H460FM
Active

Schneider Electric ComPacT NS new generation, C063H460FM, 4P MCCB, 630 A at 50 °C, MicroLogic 6.0 electronic trip unit, 70 kA Icu at 415 V AC, fixed mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C063H460FM — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indication4 LEDs (red) for fault indication 1 LED (yellow) for overload
C063H460FM — Electrical Ratings
ParameterValue
Rated current (In)630 A at 50 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz
Number of poles4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Overvoltage categoryIII
Electrical durability2000 cycles at 690 V In 4000 cycles at 690 V In/2 5000 cycles at 440 V In 6000 cycles at 440 V In/2
Mechanical durability (operating cycles)10000 cycles
C063H460FM — Identification
ParameterValue
Product nameComPacT NS new generation
Product / component typeCircuit breaker
Product range / familyComPacT
C063H460FM — Mechanical
ParameterValue
Mounting supportBackplate
Mounting modeFixed
Control typeManually operated
C063H460FM — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C063H460FM — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

630 A, 4-pole MCCB with MicroLogic 6.0 LSI protection

It carries a MicroLogic 6.0 electronic trip unit providing LSI protection — long-time (L) for overload, short-time (S) for short-time short-circuit, and instantaneous (I) for high-fault clearing. The H breaking capacity code delivers 70 kA Icu at 380/415 V AC, 50/60 Hz per IEC 60947-2, making it suitable for distribution switchboards where high fault current and selectivity are required. Rated 630 A at 50 °C, this breaker sits in the ComPacT NS630b...1600 new generation family, used for main or feeder protection in LV distribution panels. The 4P configuration with neutral left handles three-phase plus neutral loads without a separate neutral disconnect.

The H-rated frame gives 85 kA Icu at 240 V, 70 kA at 415 V, 65 kA at 440 V, and 42 kA at 690 V AC. For a 630 A main breaker on a 415 V system, 70 kA Icu provides solid short-circuit withstand for most industrial service-entrance applications — enough headroom for coordination with downstream 25–50 kA rated feeders. Category B utilization (IEC 60947-2) means it is designed for selectivity, not just cable protection.

Fixed mount on a backplate, 327 mm high × 280 mm wide × 147 mm deep. Front-side connection both top and bottom — no rear-access requirement.

Trip unit and diagnostics

MicroLogic 6.0 is fully electronic, with 20-minute thermal memory for accurate overload replay after a trip. Four red LEDs indicate fault type (long-time, short-time, instantaneous, ground fault) and one yellow LED signals overload pre-alarm — useful for field troubleshooting without plugging in a handheld. No earth-leakage protection built in; add a Vigi module externally if ground-fault protection is needed.

Frequently asked questions

What is the breaking capacity of C063H460FM at 415 V?

70 kA Icu at 380/415 V AC, 50/60 Hz per IEC 60947-2. At 440 V it drops to 65 kA; at 690 V it is still 42 kA.

Where can I buy C063H460FM?

The C063H460FM is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quote.

What protection curves does the MicroLogic 6.0 trip unit provide?

LSI: long-time (L) for overload, short-time (S) for short-time short-circuit with selectable delay for selectivity, and instantaneous (I) for high-fault clearing. No ground-fault element is included on this unit.

MPN
C063H460FM