C1032G040 ComPacT NSX MicroLogic 2.2 G Trip Unit, 40 A

MPNC1032G040
Active

Schneider Electric ComPacT NSX series, MicroLogic 2.2 G electronic trip unit, C1032G040, 40 A at 40 °C, 3 poles 3d, LSoI protection, 690 V AC.

$332.42Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C1032G040 — Identification
ParameterValue
Product rangeComPacT
Product range (series)ComPacT NSX100...250
Product/component typeTrip unit
Device applicationGenerator
C1032G040 — Ratings
ParameterValue
Poles configuration3P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
C1032G040 — Protection
ParameterValue
Trip unit technologyElectronic
Earth-leakage protectionWithout
C1032G040 — Mechanical
ParameterValue
Local signalling/indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C1032G040 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C1032G040 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C1032G040 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range18...40 A
Trip unit protection functionsLSoI

Product details

The C1032G040 is a MicroLogic 2.2 G electronic trip unit designed for Schneider Electric's ComPacT NSX100...250 molded-case circuit breaker frames. The 'G' suffix marks it for generator protection duty, which means the trip curves are shaped to handle generator inrush and fault-current profiles differently than a standard distribution trip.

The 40 A rating at 40 °C is the continuous current the trip unit can carry without tripping — the actual Ir adjustment range is 18...40 A across 9 settings, so you can dial it down to match a smaller generator or feeder. Short-time pickup Isd is adjustable from 1.5 to 9 x Ir, giving you selectivity headroom downstream. Instantaneous pickup Ii is fixed at 600 A, which clears hard faults fast. The rated operational voltage is 690 V AC at 50/60 Hz, so it handles 480 V and 600 V class systems with margin. That matters for generator paralleling or motor starting where repeated overloads can damage windings. The IP40 front face keeps tools and fingers out but is not washdown-rated.

This is a plug-in electronic trip unit that snaps into the ComPacT NSX100/160/250 breaker frame. The breaker mounts fixed in a panel or enclosure — no DIN-rail adapter needed for the trip unit itself. The 3D protected poles mean all three phase poles are monitored; there is no neutral pole protection on this variant. No earth-leakage or zone-selective interlocking on this version — keep that in mind if your generator feeder requires ground-fault coordination.

Frequently asked questions

Where can I buy C1032G040 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution channels. Submit a request with your quantity and target delivery date; availability and current pricing are confirmed at quote time.

What is C1032G040's listed range (ComPacT) on this component line?

The C1032G040 belongs to the ComPacT NSX100...250 range of molded-case circuit breakers.

What is C1032G040's listed standards (EN/IEC 60947-2) on this component line?

The trip unit complies with EN/IEC 60947-2, the standard for low-voltage switchgear and controlgear.

What protection functions does the MicroLogic 2.2 G provide?

It provides LSoI protection: long-time overload (L), short-time short-circuit with fixed delay (So), and instantaneous short-circuit (I). The 'G' designation tailors the curves for generator application.