Skip to main content
Schneider Electric C1036M025 — Residual Current Breakers (RCCB/RCBO)

C1036M025 ComPacT NSX MicroLogic 6.2 E-M Trip Unit, 25 A, 3P

MPNC1036M025
Active

Schneider Electric ComPacT NSX series, MicroLogic 6.2 E-M electronic trip unit, order code C1036M025, 25 A at 65 °C, 3P, LSIG protection for motor applications.

$332.55 – $553.78Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C1036M025 — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point
C1036M025 — Electrical Ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
C1036M025 — Identification
ParameterValue
Product / component typeTrip unit
Product range / familyComPacT
C1036M025 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C1036M025 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The C1036M025 is a MicroLogic 6.2 E-M electronic trip unit from the ComPacT NSX100...250 range, rated 25 A at 65 °C. It fits 3-pole ComPacT NSX circuit breakers and provides LSIG protection — long-time (L), short-time (S), instantaneous (I), and ground-fault (G) — specifically tuned for motor loads. The 25 A rating at 65 °C means it holds its full ampacity even in a warm panel, so no derating headache for a motor circuit that runs near that ambient.

Built to EN/IEC 60947-2, this trip unit uses electronic sensing with an LCD display for local readout of energy metering, protection settings, and event logs. Motor tripping classes 5, 10, 20, and 30 are selectable, so you match the overload curve to the motor's thermal withstand.

The long-time pickup (Ir) adjusts from 12 to 25 A, and the short-time pickup (Isd) has nine adjustable settings from 5 to 13 x Ir. Ground-fault pickup (Ig) is adjustable as well. Instantaneous pickup (Ii) is fixed. Zone selective interlocking (ZSI) is included, which helps coordinate downstream breakers for faster fault clearing without losing selectivity upstream.

Frequently asked questions

What is C1036M025 used for?

It is an electronic trip unit for ComPacT NSX100...250 circuit breakers, designed for motor protection with LSIG functions and selectable tripping classes.

Where can I buy C1036M025?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What standards does C1036M025 comply with?

It complies with EN/IEC 60947-2.

MPN