Schneider Electric C1036M050 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C1036M050 MicroLogic 6.2 E-M Trip Unit, 5

MPNC1036M050
Obsolete

Schneider Electric ComPacT NSX series, MicroLogic 6.2 E-M electronic trip unit, 50 A at 65 °C, 3-pole, LSIG protection, EN/IEC 60947-2.

$313.73Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C1036M050 — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point
C1036M050 — Electrical Ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
C1036M050 — Identification
ParameterValue
Product / component typeTrip unit
Product range / familyComPacT
C1036M050 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C1036M050 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C1036M050 is a MicroLogic 6.2 E-M electronic trip unit from the ComPacT NSX100...250 range, designed for fixed-mount circuit breakers protecting motor loads. It carries a trip unit rating of 50 A at 65 °C and a rated operational voltage of 690 V AC 50/60 Hz. The 3-pole, 3D protected configuration with LSIG protection functions means it handles overload (L), short-time short-circuit (S), instantaneous short-circuit (I), and ground-fault (G) protection — the full set for a motor feeder.

Motor protection specifics

The E-M designation means this trip unit is purpose-built for motor applications. It offers complementary motor protection functions including protracted starting time, underload, current unbalance, and stalled rotor detection. The motor tripping class is selectable among 10, 20, 30, 5 — class 30 is typical for high-inertia loads like fans or conveyors where starting current can persist for tens of seconds. The long-time protection delay adjustment range (Tr) varies by trip class: for class 5, 120 s at 1.5 x Ir; for class 30, 720 s at 1.5 x Ir. That range lets you match the trip curve to the motor's actual start profile. Short-time protection pickup (Isd) is adjustable across 9 settings from 5 to 13 x Ir. Instantaneous pickup (Ii) is fixed. Ground-fault pickup (Ig) is adjustable. Zone selective interlocking (ZSI) is included, which speeds up fault clearing by coordinating trip delays between downstream and upstream breakers — useful in a motor control center with multiple feeders.

The trip unit mounts into a ComPacT NSX fixed circuit breaker.

Frequently asked questions

How do I get current pricing and availability for C1036M050?

Submit an RFQ against the C1036M050 order code. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is C1036M050's listed range and standards?

The C1036M050 belongs to the ComPacT range and complies with EN/IEC 60947-2, the standard for low-voltage switchgear and controlgear.

What motor protection features does the MicroLogic 6.2 E-M offer?

The trip unit provides LSIG protection (overload, short-time short-circuit, instantaneous short-circuit, ground fault) plus complementary motor protection including protracted starting time, underload, current unbalance, and stalled rotor detection.