Schneider Electric C103MA003 — Miniature Circuit Breakers (MCB)

Schneider Electric C103MA003 ComPacT NSX Trip Unit, 2.5 A, M

MPNC103MA003
Active

Schneider Electric ComPacT NSX100...250, trip unit MA2.5, magnetic, 2.5 A, 3 poles 3D, for motor short-circuit protection.

$123.03 – $159.03Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C103MA003 — Identification
ParameterValue
Product rangeComPacT
Product range (series)ComPacT NSX100...250
Product/component typeTrip unit
Device applicationMotor
C103MA003 — Ratings
ParameterValue
Poles configuration3P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
C103MA003 — Protection
ParameterValue
Trip unit technologyMagnetic
Earth-leakage protectionWithout
C103MA003 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C103MA003 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C103MA003 — Specifications
ParameterValue
Trip unit protection functionsI

Product details

The C103MA003 is a magnetic-only trip unit from the Schneider Electric ComPacT NSX series, designed for motor short-circuit protection in AC networks. It carries a 2.5 A rating at 65 °C and fits the NSX100...250 frame. The MA designation means it provides instantaneous magnetic protection only — no thermal overload element — so it relies on a separate motor starter or overload relay for running overcurrent protection. This is standard practice for motor branch circuits where the trip unit handles the short-circuit fault and the starter handles the overload.

The instantaneous pick-up is adjustable across nine settings from 6× to 14× In (15 A to 35 A at the 2.5 A rating). That range lets you set the magnetic trip threshold high enough to avoid nuisance trips on motor inrush (typically 6–8× FLA) while still clearing a bolted fault. The 3-pole 3D protected poles description means all three poles are protected and the trip unit switches the line conductors. The IP40 enclosure rating on the trip unit itself is sufficient for panel-mount applications where the breaker is behind a closed door. There is no earth-leakage protection integrated — that function would need a separate Vigi module or an external RCD.

Motor duty and coordination

This trip unit is specifically listed for motor application (Device application: Motor). The magnetic-only characteristic is intentional: in a motor branch circuit, the thermal overload is handled by the starter's overload relay (typically a TeSys LR or similar), and the trip unit only needs to clear short-circuits. The adjustable instantaneous setting lets you coordinate with the starter's withstand rating. For a 2.5 A motor (roughly 0.75 kW at 400 V), setting the magnetic trip to 10× In (25 A) would ride through a normal start while still protecting the cable and contactor against a phase-to-phase fault.

Frequently asked questions

Where can I buy C103MA003 and how do I get a price?

The C103MA003 is available to order through independent distribution. Submit an RFQ for current pricing and availability — both are confirmed at quote time.

What is C103MA003's listed range (ComPacT) on this component line?

The C103MA003 belongs to the Schneider Electric ComPacT NSX100...250 range of molded-case circuit breakers and accessories.

What is C103MA003's listed standards (EN/IEC 60947-2) on this component line?

The C103MA003 complies with EN/IEC 60947-2, the standard for low-voltage switchgear and controlgear — specifically for circuit breakers. This covers the trip unit's performance under fault conditions and its coordination requirements.

MPN
C103MA003