Schneider Electric C103TM040C

Schneider Electric C103TM040C ComPacT NSX TM-D Trip Unit, 40

MPN C103TM040C
Active

Schneider Electric ComPacT NSX100-250, TM-D trip unit, thermal-magnetic, 40 A at 50 °C, 3 poles 3D, EN/IEC 60947-2, IP40.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C103TM040C specifications
ParameterValue
Trip unit typeThermal-magnetic
Main product or component typeTrip unit
Voltage690 V AC 50/60 Hz 750 V DC
IP ratingIP40
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degree3 conforming to IEC 60947-1
ApplicationDistribution
Operating temperature-25...70 °C

Product details

Trip unit for ComPacT NSX100-250

The C103TM040C is a TM-D thermal-magnetic trip unit for the Schneider Electric ComPacT NSX100-250 range, rated 40 A at 50 °C. It provides LI protection — thermal overload (L) and magnetic short-circuit (I) — across three protected poles (3D). The fixed instantaneous pickup trips at 500 A, and the long-time pickup is adjustable from 0.7 to 1.0 × In. This is the distribution-grade version, without earth-leakage detection.

The 500 A instantaneous pickup (Ii) is fixed — roughly 12.5 × In — so it clears hard shorts fast but may not coordinate with downstream 10 kA MCBs on a high-fault bus. The TM-D trip unit is non-interchangeable in the field — it's a fixed thermal-magnetic design with a sealed housing. The long-time delay (tr) is fixed at 120–400 s at 1.5 × In and 15 s at 6 × Ir, which suits distribution feeders rather than motor-starting profiles. For motor loads, a TM-G or electronic Micrologic trip unit would be a better fit.

The trip unit mounts into a ComPacT NSX100-250 fixed or plug-in circuit breaker. The breaker itself is IP40 front-face protected (finger-safe), suitable for enclosed panel mounting. The 3D pole configuration means the trip unit protects all three phases but does not include a neutral pole — use a 4P breaker if neutral protection is needed. No auxiliary contacts or shunt trip are integrated; those are add-on accessories that clip onto the breaker side.

MPN
C103TM040C