Active

Schneider Electric ComPacT NSX100...250, MicroLogic 4.2 AL electronic trip unit, 40 A at 40 °C, 4P, EN/IEC 60947-2, integrated earth-leakage protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C1044A040 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload Color indicator (yellow) for residual current
C1044A040 — Electrical Ratings
ParameterValue
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
C1044A040 — Identification
ParameterValue
Product / component typeTrip unit
Product range / familyComPacT
C1044A040 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C1044A040 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C1044A040 is a MicroLogic 4.2 AL electronic trip unit for the ComPacT NSX100...250 range, rated 40 A at 40 °C with 4 poles (4P). The trip unit integrates earth-leakage protection (Class A) and provides LSoI protection functions: long-time (L), short-time (So), and instantaneous (I) short-circuit protection, plus overload protection.

Protection settings and adjustment ranges

The long-time protection pick-up (Ir) is adjustable from 18 to 40 A, with fixed delay settings: 400 s at 1.5 x Ir, 16 s at 6 x Ir, and 11 s at 7.2 x Ir. The short-time protection pick-up (Isd) adjusts from 1.5 to 10 x Ir with a fixed delay. Instantaneous protection (Ii) is fixed at 600 A. Earth-leakage sensitivity (IΔn) and time delay (Δt) are both adjustable. The neutral protection settings offer three options: 0.5 x Ir (3D + N/2), 1 x Ir (4D), or no protection (3D).

Rated for ambient air temperatures from -25 to 70 °C during operation and -40 to 85 °C in storage. IP40 protection per IEC 60529. The trip unit mounts fixed in the ComPacT NSX breaker; neutral position is left. Local signalling includes a flashing green LED for ready status, red LED at 105% Ir for overload, orange LED at 90% Ir for overload, and a yellow indicator for residual current.

Frequently asked questions

What is the C1044A040's rated current and voltage?

The trip unit is rated 40 A at 40 °C with a rated operational voltage of 440 V AC at 50/60 Hz.

What protection functions does the MicroLogic 4.2 AL provide?

It provides LSoI protection: long-time overload (L), short-time short-circuit (So) with fixed delay, and instantaneous short-circuit (I). Integrated earth-leakage protection is Class A.

What standards does the C1044A040 comply with?

The trip unit complies with EN/IEC 60947-2 for low-voltage switchgear and controlgear.

Where can I buy the C1044A040?