Skip to main content
Schneider Electric C1046E040 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C1046E040 MicroLogic 6.2 E Trip Unit, 40

MPNC1046E040
Obsolete

Schneider Electric ComPacT NSX, MicroLogic 6.2 E electronic trip unit, 40 A at 40 °C, 4P, LSIG protection, EN/IEC 60947-2, LCD display, current lifecycle stage.

$211.91Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C1046E040 — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C1046E040 — Electrical Ratings
ParameterValue
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
C1046E040 — Identification
ParameterValue
Product / component typeTrip unit
Product range / familyComPacT
C1046E040 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C1046E040 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

Trip unit for ComPacT NSX — MicroLogic 6.2 E, 40 A, LSIG

The Schneider Electric C1046E040 is a MicroLogic 6.2 E electronic trip unit for the ComPacT NSX100...250 molded-case circuit breaker platform. It is rated 40 A at 40 °C (Ir adjustable 18...40 A) and provides LSIG protection — long-time (L), short-time (S), instantaneous (I), and ground-fault (G) — per EN/IEC 60947-2. The 4-pole unit (4P) is designed for distribution applications on 50/60 Hz networks up to 690 V AC.

Protection coordination and selectivity

LSIG protection covers the full fault spectrum: L (long-time) adjustable 15...400 s at 1.5×Ir, S (short-time) adjustable 0...0.4 s with I²t on/off, I (instantaneous) adjustable, and G (ground-fault) adjustable. Zone selective interlocking (ZSI) is built in — this lets multiple breakers in a cascade communicate fault direction, reducing trip time on a downstream fault while maintaining selectivity upstream. For a site electrical engineer coordinating a distribution panel, ZSI means you can set tighter short-time delays without losing coordination. Neutral protection is configurable: 0.5×Ir (3D+N/2), 1×Ir (4D), 1.6×Ir (3D+OSN), or no protection (3D). This covers both fully rated and reduced-neutral distribution schemes.

The trip unit mounts into a ComPacT NSX100...250 fixed-mount breaker. The 4-pole unit occupies the left neutral position. IP40 front protection (IEC 60529) keeps tools and fingers out but is not sealed against washdown. Communication data includes energy metering, protection and alarm settings, time-stamped event tables, instantaneous and demand values, maintenance indicators, and power quality metrics. The LCD display shows local readouts without needing a connected controller.

Frequently asked questions

What are the LSIG protection settings on C1046E040?

LSIG stands for long-time (L), short-time (S), instantaneous (I), and ground-fault (G) protection. The Ir (long-time pickup) is adjustable 18...40 A; tr (delay) adjustable 15...400 s at 1.5×Ir. Isd (short-time pickup) has 9 adjustable settings; tsd delay adjustable 0...0.4 s with I²t on/off. Ii (instantaneous) is adjustable. Ig (ground-fault pickup) is adjustable. Zone selective interlocking (ZSI) is included.

What standards does C1046E040 comply with?

The C1046E040 complies with EN/IEC 60947-2, the standard for low-voltage switchgear and controlgear — circuit-breakers. Pollution degree 3 per IEC 60947-1. IP40 per IEC 60529.

Where can I buy C1046E040 and get current pricing?

The C1046E040 is available to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time.

MPN
C1046E040