Skip to main content
Schneider Electric C106MA100 — Miniature Circuit Breakers (MCB)

C106MA100 ComPacT NSX MA100 trip unit, 100 A, motor protecti

MPNC106MA100
Active

Schneider Electric ComPacT NSX100-250, trip unit MA100, magnetic, 100 A, 4P 3D, motor short-circuit protection, EN/IEC 60947-2.

$110.08 – $138.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C106MA100 — Identification
ParameterValue
Product rangeComPacT
Product range (series)ComPacT NSX100...250
Product/component typeTrip unit
Device applicationMotor
C106MA100 — Ratings
ParameterValue
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz
Network type (AC/DC)AC
Network frequency50/60 Hz
C106MA100 — Protection
ParameterValue
Trip unit technologyMagnetic
Earth-leakage protectionWithout
C106MA100 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C106MA100 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C106MA100 — Specifications
ParameterValue
Trip unit protection functionsI

Product details

The C106MA100 is a magnetic-only trip unit from the ComPacT NSX100...250 range, designed for motor short-circuit protection (protection type I) in AC networks. It carries a 100 A rating at 65 °C, so it's sized for a motor full-load current up to that thermal limit — the magnetic element handles fault clearing, not overload. The instantaneous pick-up is adjustable from 6 to 14 times In (600 A to 1400 A), which lets you set the magnetic threshold above the motor's starting inrush without nuisance tripping. This is a 4-pole unit with 3 protected poles (3D) — the neutral pole is unprotected, so it's intended for three-phase motor circuits where the neutral carries no load.

Fixed-mount trip unit for ComPacT NSX100, NSX160, or NSX250 molded-case circuit breakers. The neutral position is left, and the unit snaps into the breaker's trip-unit cradle — no wiring required beyond the breaker's own terminals. IP40 protection (IEC 60529) covers the trip unit itself; the overall breaker enclosure may carry a higher rating. Ambient operating range is -25 to 70 °C, storage from -50 to 85 °C — fine for most indoor panel installations, though you'll want to check the breaker's own derating curve if the panel ambient exceeds 40 °C.

Frequently asked questions

What is C106MA100 used for?

It is a magnetic trip unit for motor short-circuit protection in ComPacT NSX100-250 circuit breakers. It provides adjustable instantaneous magnetic protection (6-14 x In) but no overload protection — an external overload relay is required.

What standards does C106MA100 comply with?

It complies with EN/IEC 60947-2 (low-voltage switchgear and controlgear — circuit-breakers). Pollution degree 3 per IEC 60947-1, and IP40 per IEC 60529.

Where can I buy C106MA100?

The C106MA100 is sourced and quoted to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

MPN
C106MA100