Schneider Electric C106TM032C — Miniature Circuit Breakers (MCB)

Schneider C106TM032C ComPacT NSX TM-D Trip Unit, 32 A, 4P

MPNC106TM032C
Active

Schneider Electric ComPacT NSX100...250, TM-D trip unit, thermal-magnetic, 32 A at 50 °C, 4 poles 3D, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C106TM032C — Identification
ParameterValue
Product rangeComPacT
Product range (series)ComPacT NSX100...250
Product/component typeTrip unit
Device applicationDistribution
C106TM032C — Ratings
ParameterValue
Poles configuration4P
Rated operational voltage (Ue)690 V AC 50/60 Hz 750 V DC
Network type (AC/DC)AC DC
Network frequency50/60 Hz
C106TM032C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
C106TM032C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60947-1
C106TM032C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C106TM032C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The C106TM032C is a Schneider Electric ComPacT NSX thermal-magnetic trip unit, rated 32 A at 50 °C, designed for the NSX100...250 frame. It provides LI protection — thermal overload (L) and magnetic short-circuit (I) — in a 4-pole, 3D configuration (three protected poles, neutral unprotected). The instantaneous magnetic pickup is fixed at 400 A, meaning a fault current above that level trips the breaker without intentional delay. The unit carries an IP40 protection rating, suitable for installation inside an enclosed panel where dust ingress is limited.

If your panel runs hotter — say 60 °C — you need to derate or step up to a higher amp frame. The long-time pickup (Ir) is adjustable from 0.7 to 1.0 x In (22.4 to 32 A), letting you fine-tune the overload threshold to match the downstream cable or load without swapping the trip unit. The fixed instantaneous pickup at 400 A (12.5 x In) is a deliberate choice: it avoids nuisance tripping on motor inrush or capacitor bank charging current, but it also means the short-circuit protection threshold is not adjustable. For a distribution board feeding mixed loads — lighting, small motors, control transformers — this fixed band is usually fine. If you need a lower Ii for a sensitive branch, look at the TM-D variants with adjustable magnetic pickup.

That covers everything from dielectric withstand to temperature rise limits and breaking capacity.

Frequently asked questions

What are the key ratings of C106TM032C?

32 A continuous rating at 50 °C, 690 V AC / 750 V DC rated operational voltage, 4 poles with 3 protected poles (3D), fixed instantaneous magnetic pickup at 400 A, and adjustable thermal overload pickup from 0.7 to 1.0 x In.

What standard does C106TM032C comply with?

It is designed and tested to EN/IEC 60947-2, the international standard for low-voltage circuit-breakers used in distribution and motor control.

Where can I buy C106TM032C and get current pricing?

The C106TM032C is sourced to order through independent distribution. Submit an RFQ to get current pricing and availability confirmed at quote time.