Skip to main content
Schneider Electric C10B34V040

Schneider Electric C10B34V040 ComPacT NSX MCCB, 40 A, 40 kA

MPN C10B34V040
Active

Schneider Electric ComPacT NSX, NSX100B, earth leakage circuit breaker, 3P, 40 A at 40 °C, 40 kA Icu at 240 V AC, MicroLogic 4.2 electronic trip unit.

$1,014.60 – $1,882.44 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10B34V040 key specifications
ParameterValue
Control typeToggle
Trip unit typeElectronic
Main product or component typeEarth leakage circuit breaker
Voltage440 V AC 50/60 Hz
Insulation voltage ui500 V AC 50/60 Hz
Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C10B34V040 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical life cycles50000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

It's a 3-pole unit rated 40 A at 40 °C, with an integrated MicroLogic 4.2 electronic trip unit that provides overload (L), short-time short-circuit (So), instantaneous (I), and earth-leakage (R) protection. At 415 V AC the breaking capacity is 25 kA Icu, and at 440 V it's 20 kA Icu, all per IEC 60947-2. That standard certifies the breaker for industrial application, not just residential.

Deployment context

Mounts on a backplate in a distribution panel — horizontal or vertical orientation, flat on the back. The toggle control and front connections (both upside and downside) make it straightforward to wire in a panel layout. Mechanical durability is 50,000 cycles; electrical durability ranges from 50,000 cycles at 440 V at half rated current down to 10,000 cycles at 690 V at full rated current — so if you're switching near its limits frequently, factor that in.

MPN
C10B34V040