C10F1TM030 ComPacT NSX100F 30A 1P 18kA MCCB

MPN C10F1TM030
Active

Schneider Electric ComPacT NSX100F, 1-pole thermal-magnetic MCCB, 30 A at 40 °C, 18 kA breaking capacity at 240 V AC.

$74.43 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10F1TM030 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage277 V AC 50/60 Hz 250 V DC
Insulation voltage ui750 V AC 50/60 Hz conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C
Temp operating max70 °C

All specifications

C10F1TM030 additional specifications
ParameterValue
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width35 mm
Height161 mm
Electrical life cycles20000 cycles at 277 V In/2 10000 cycles at 277 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The Schneider Electric C10F1TM030 is a ComPacT NSX100F circuit breaker, 1-pole, with a TM-D thermal-magnetic trip unit rated 30 A at 40 °C. It breaks 18 kA Icu at 240 V AC (50/60 Hz) per IEC 60947-2, and 36 kA Icu at 250 V DC — that DC rating is unusual for a single-pole frame this size, useful if you are isolating a DC bus in a pitch-control cabinet or brake resistor circuit up-tower.

The 36 kA at 250 V DC is a separate rating — do not assume the same performance at 125 V DC or 48 V DC; consult the coordination tables if you are using it on a battery bank. The TM-D trip unit provides thermal overload protection (L) and magnetic short-circuit protection (I). At 30 A and 40 °C ambient, the thermal element tracks RMS current; below 40 °C it trips slightly slower, above 40 °C you must derate per the IEC 60947-2 thermal curve. The magnetic pickup is fixed at roughly 10× In (300 A), so it will not nuisance-trip on motor inrush unless the motor draws over 300 A locked-rotor.

Mounts on a backplate — not DIN-rail — so plan for screw-down fixing with the 35 mm pole pitch aligning to busbar or cable lugs. The 161 mm height and 86 mm depth fit a standard enclosure, but the 35 mm width per pole means a 1-pole unit occupies one module slot. Front connections top and bottom simplify busbar runs in a distribution board. The IK07 impact rating means it survives a 2 J hammer blow during panel assembly.

MPN