Skip to main content
Schneider Electric C10F2TM016

Schneider C10F2TM016 ComPacT NSX100F 16A MCCB, 36kA 240V

MPN C10F2TM016
Active

Schneider Electric ComPacT NSX100F, C10F2TM016, 2-pole thermal-magnetic MCCB, 16 A rated, 36 kA breaking capacity at 240 V AC.

$175.68 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10F2TM016 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz 500 V DC
Insulation voltage ui750 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity36 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380/415 V AC 50/60 Hz 1P conforming to IEC 60947-2 15 kA Icu at 440 V AC 50/60 Hz 1P conforming to IEC 60947-2 10 kA Icu at 500/525 V AC 50/60 Hz 2P conforming to IEC 60947-2 5 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 250 V DC 50/60 Hz 1 pole conforming to IEC 60947-2 36 kA Icu at 500 V DC 50/60 Hz 2 poles in series conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C10F2TM016 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width70 mm
Height161 mm
Electrical life cycles20000 cycles at 277 V In/2 10000 cycles at 277 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

What this MCCB brings to a panel

The C10F2TM016 is a Schneider ComPacT NSX100F moulded-case circuit breaker, 2-pole, thermal-magnetic trip unit set at 16 A at 40 °C. It's an active-production part, so no lifecycle surprises when you're filling a BOM or stocking a spare for a distribution board. Mounts on a backplate or flat panel surface, 70 mm wide, 161 mm tall, 86 mm deep.

Trip curve and protection logic

The TM-D trip unit gives you thermal overload protection (L) and magnetic short-circuit protection (I) — no electronic adjustment, no earth-leakage module. For a 16 A circuit feeding lighting, small motor groups, or general distribution, that's a straightforward, field-proven curve that doesn't need a laptop to commission.

MPN
C10F2TM016