Skip to main content
Schneider Electric C10F2TM080

Schneider Electric C10F2TM080 ComPacT NSX100F Circuit Breake

MPN C10F2TM080
Active

Schneider Electric ComPacT NSX100F, 2-pole circuit breaker, 80 A thermal-magnetic TM-D trip unit, 18 kA Icu at 415 V AC, IP40, toggle control.

$175.68 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10F2TM080 key specifications
ParameterValue
Control typeToggle
Trip unit typeThermal-magnetic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz 500 V DC
Insulation voltage ui750 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity36 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 18 kA Icu at 380/415 V AC 50/60 Hz 1P conforming to IEC 60947-2 15 kA Icu at 440 V AC 50/60 Hz 1P conforming to IEC 60947-2 10 kA Icu at 500/525 V AC 50/60 Hz 2P conforming to IEC 60947-2 5 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 250 V DC 50/60 Hz 1 pole conforming to IEC 60947-2 36 kA Icu at 500 V DC 50/60 Hz 2 poles in series conforming to IEC 60947-2
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C10F2TM080 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width70 mm
Height161 mm
Electrical life cycles20000 cycles at 277 V In/2 10000 cycles at 277 V In
Mechanical life cycles20000 cycles
ApplicationDistribution
Operating temperature-25...70 °C

Product details

The C10F2TM080 is a Schneider Electric ComPacT NSX100F 2-pole fixed-mount circuit breaker with an 80 A thermal-magnetic TM-D trip unit. This is the rating that governs fault interruption on a 400 V line: at 415 V it clears 18 kA symmetrical, enough for most commercial and light industrial panelboards without cascading upstream. The TM-D trip provides L (thermal overload) and I (magnetic short-circuit) protection, with the thermal element calibrated at 40 °C ambient.

The C10F2TM080 is listed as current production.

IP40 front face and IK07 impact resistance handle normal panel service.

Mounting & Connections

Fixed backplate mount, accepts horizontal or vertical orientation. Front-facing connections top and bottom — 35 mm pitch. The 2-pole form factor (70 mm wide, 161 mm high, 86 mm deep) fits standard panel cutouts.

MPN
C10F2TM080