Schneider Electric C10F3MA007 — Miniature Circuit Breakers (MCB)

Schneider Electric C10F3MA007 ComPacT NSX100F, 6.3 A Magneti

MPNC10F3MA007
Active

Schneider Electric ComPacT NSX NSX100F, 3-pole circuit breaker, 6.3 A magnetic-only MA trip unit, 36 kA breaking capacity at 415 V AC, IP40, backplate mount.

$160.69 – $410.89Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C10F3MA007 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationMotor protection
C10F3MA007 — Ratings
ParameterValue
Rated current (In)6.3 A at 65 °C
Poles configuration3P
Breaking capacity85 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 22 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 25 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
Rated service breaking capacity (Ics)85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 11 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 4 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10F3MA007 — Protection
ParameterValue
Trip unit technologyMagnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (cycles)50000 cycles
C10F3MA007 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10F3MA007 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10F3MA007 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10F3MA007 — Specifications
ParameterValue
Trip unit protection functionsI

Product details

Motor-protection circuit breaker with magnetic-only trip

Rated 85 kA Icu at 240 V AC and 36 kA Icu at 415 V AC (per IEC 60947-2), it sits in the F breaking-capacity tier, which is the standard choice for most industrial distribution panels where fault levels stay under 36 kA at 400 V. The 3-pole configuration (3P) with front-front connections and a toggle control handle makes it a direct panel-mount fit on a backplate.

Because it is magnetic-only (protection type I for short-circuit), it does not provide overload protection; the motor's thermal protection comes from a separate device. IP40 front-face protection keeps tools and fingers out but is not washdown-rated. Mechanical durability is 50,000 cycles, electrical durability ranges from 50,000 cycles at 440 V at half rated current down to 10,000 cycles at full 690 V rated current.

Connection pitch is 35 mm, compatible with standard busbar systems. The toggle handle protrudes forward; allow finger clearance for operation.

Frequently asked questions

What is the breaking capacity of C10F3MA007 at 415 V?

36 kA Icu at 380/415 V AC 50/60 Hz per IEC 60947-2. At 240 V it is 85 kA Icu; at 690 V it derates to 8 kA Icu.

Does C10F3MA007 provide motor overload protection?

No — the MA trip unit is magnetic-only, providing short-circuit protection (type I). Overload protection must be handled by a separate thermal overload relay or motor starter.

What compliance standards does C10F3MA007 meet?

It is certified to EN/IEC 60947-2 and UL 60947-4-1. Pollution degree 3 per IEC 60664-1, overvoltage category III, and suitability for isolation per EN/IEC 60947-2.

Where can I buy C10F3MA007 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN
C10F3MA007