Schneider Electric C10H3MA025

Schneider Electric C10H3MA025 ComPacT NSX 25A MCCB, 70kA 415

MPN C10H3MA025
Active

Schneider Electric ComPacT NSX, NSX100H, 3P, 25 A magnetic-only trip unit (MA), 70 kA Icu at 415 V AC, toggle control.

$340.07 – $552.58 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10H3MA025 key specifications
ParameterValue
Control typeToggle
Trip unit typeMagnetic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
Breaking capacity100 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 70 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 65 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 240 V AC 50/60 Hz conforming to UL 60947-4-1 65 kA Icu at 480 V AC 50/60 Hz conforming to UL 60947-4-1 10 kA Icu at 600 V AC 50/60 Hz conforming to UL 60947-4-1
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-50 °C

All specifications

C10H3MA025 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-50...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical life cycles50000 cycles
ApplicationMotor protection
Operating temperature-25...70 °C

Product details

Motor-protection MCCB with magnetic-only trip

It is designed specifically for motor protection, where the upstream breaker handles short-circuit faults while the motor starter's overload relay manages thermal protection. The magnetic-only trip responds to fault currents only — no thermal element — so it coordinates cleanly with a separate overload relay downstream. Rated 70 kA Icu at 415 V AC (50/60 Hz) per IEC 60947-2, this H-frame breaker clears high fault currents typical in industrial distribution panels. At 480 V AC the interrupting rating is 65 kA Icu per UL 60947-4-1, making it suitable for North American motor branch circuits as well.

The 25 A MA trip unit is sized for motor full-load current, not cable protection. Because it lacks thermal protection, you pair it with a thermal overload relay (e.g., TeSys LR series) set to the motor nameplate FLA. The magnetic pickup is fixed and non-adjustable on the MA trip — it trips instantaneously on short-circuit, leaving the overload relay to handle running overcurrents. In a 480 V panel with a 65 kA available fault current, the C10H3MA025 holds its rating without requiring a current-limiting upstream fuse. The IP40 front face keeps tools and fingers out; the backplate mount and 35 mm connection pitch match standard DIN-rail or direct-panel layouts.