Skip to main content
Schneider Electric C10H47E100 — Residual Current Breakers (RCCB/RCBO)

Schneider C10H47E100 ComPacT NSX100H 4-pole MCCB, 100 A, 100 kA ICu

MPNC10H47E100
Obsolete

Schneider C10H47E100 Compact Nsx, New Generation — now discontinued, supplied from remaining surplus and broker stock.

$1,634.18Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10H47E100 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C10H47E100 — Electrical Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (operating cycles)50000 cycles
C10H47E100 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX100H
C10H47E100 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C10H47E100 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C10H47E100 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

Overview

The C10H47E100 is a 4-pole ComPacT NSX100H molded case circuit breaker from Schneider, rated 100 A with a 100 kA ICu breaking capacity at 440 V AC, fitted with a MicroLogic 7.2 E electronic trip unit. The trip unit provides LSI+R protection (overload, short-time, instantaneous, earth-leakage) and includes an LCD display for time-stamped events, energy metering, and power quality data. It complies with EN/IEC 60947-2, rated for pollution degree 3, with 8000 V impulse withstand and 500 V AC insulation voltage.

Compared to the 3-pole C10F3TM025 (25 A, 85 kA ICu), the C10H47E100 adds a fourth pole, quadruples the continuous current to 100 A, and raises the ICu to 100 kA — choose the C10F3TM025 only when the BOM specifies 3 poles and a lower 25 A frame.

MPN
C10H47E100