Skip to main content
Schneider Electric C10M1TM025 — Miniature Circuit Breakers (MCB)

Schneider Electric C10M1TM025 ComPacT NSX100M, 25 A, 1P, 40

MPNC10M1TM025
Active

Schneider Electric ComPacT NSX100M, C10M1TM025, 1-pole 25 A thermal-magnetic circuit breaker, 40 kA Icu at 240 V AC, TM-D trip unit.

$2.52Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

C10M1TM025 — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10M1TM025 — Ratings
ParameterValue
Rated current (In)25 A at 40 °C
Poles configuration1P
Breaking capacity40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 85 kA Icu at 250 V DC conforming to IEC 60947-2
Rated service breaking capacity (Ics)40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 85 kA at 250 V DC conforming to IEC 60947-2
Rated operational voltage (Ue)277 V AC 50/60 Hz 250 V DC
Rated insulation voltage (Ui)750 V AC 50/60 Hz conforming to IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to IEC 60947-2
Network type (AC/DC)AC DC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIV
C10M1TM025 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)20000 cycles at 277 V In/2 10000 cycles at 277 V In
Mechanical durability (cycles)20000 cycles
C10M1TM025 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10M1TM025 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10M1TM025 — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10M1TM025 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range1 x In
Trip unit protection functionsLI

Product details

The Schneider Electric C10M1TM025 is a ComPacT NSX100M circuit breaker, 1-pole, rated 25 A at 40 °C with a TM-D thermal-magnetic trip unit. The 1P format with toggle control and front connections makes it a direct swap in a fixed-mount panel layout.

The TM-D trip provides L (thermal overload) and I (magnetic short-circuit) protection — the thermal element handles sustained overloads, the magnetic element trips instantaneously on high faults. Overvoltage category IV confirms it's suitable for main distribution panels at the service entrance, not just downstream sub-panels. The IP40 enclosure protection keeps out tools and small objects but not water; mount it inside a sealed cabinet for washdown areas. Mechanical durability of 20,000 cycles and electrical durability of 20,000 cycles at 277 V at half rated current (In/2) or 10,000 cycles at full rated current give a realistic service life for a distribution breaker — it's not a motor-switching contactor, but it handles occasional load-break operations without accelerated wear.

Fixed-mount on a backplate, 35 mm width per pole, 161 mm height, 86 mm depth.

Frequently asked questions

Where can I buy C10M1TM025 and how is it quoted?

The C10M1TM025 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of C10M1TM025?

The C10M1TM025 has a breaking capacity of 40 kA Icu at 240 V AC (IEC 60947-2) and 85 kA Icu at 250 V DC.

What standards does C10M1TM025 comply with?

The C10M1TM025 complies with EN/IEC 60947-2 and is suitable for isolation per that standard. It also meets pollution degree 3 (IEC 60664-1) and overvoltage category IV.

MPN
C10M1TM025