Schneider Electric C10N3TM080C — Miniature Circuit Breakers (MCB)

C10N3TM080C ComPacT NSX 80A 3P Circuit Breaker, 50kA 415V

MPNC10N3TM080C
Active

Schneider Electric ComPacT NSX, C10N3TM080C, 3-pole 80 A thermal-magnetic circuit breaker, 50 kA Icu at 415 V AC, IP40, backplate mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10N3TM080C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10N3TM080C — Ratings
ParameterValue
Rated current (In)80 A at 50 °C
Poles configuration3P
Breaking capacity90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10N3TM080C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (cycles)50000 cycles
C10N3TM080C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10N3TM080C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10N3TM080C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10N3TM080C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The C10N3TM080C is a Schneider Electric ComPacT NSX100N frame circuit breaker, 3-pole, rated 80 A at 50 °C with a thermal-magnetic TM-D trip unit. Breaking capacity is 50 kA Icu at 380/415 V AC and 440 V AC, 36 kA at 500 V, and 10 kA at 660/690 V — that's N-frame performance (50 kA at 415 V). For a panel fed from a transformer in the 500–1000 kVA range, this holds selectivity with upstream fuses or a higher-rated breaker. The TM-D trip provides L (thermal overload) and I (magnetic short-circuit) protection. Thermal pickup is fixed at the 80 A rating; magnetic pickup is fixed and not field-adjustable — typical for distribution where you want simple, repeatable coordination.

IP40 enclosure protection (no washdown rating) and IK07 impact resistance.

Durability and ratings

Mechanical endurance is 50,000 cycles; electrical endurance at rated current (80 A, 440 V) is 30,000 cycles, rising to 50,000 at half-load. That's solid for a distribution breaker in a panel that sees regular switching — say a process line that cycles daily for years. Power dissipation is 8.77 W per pole, so 26.3 W total at full load.

Frequently asked questions

Where can I buy C10N3TM080C?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the breaking capacity of C10N3TM080C at 415 V?

50 kA Icu at 380/415 V AC, 50/60 Hz, per IEC 60947-2.

What is the closest alternative to C10N3TM080C?

The ComPacT NSX family includes other frame sizes and trip ratings; the C10N3TM080C is a specific 80 A, 3-pole, N-frame variant. For a different rating, stay within the NSX100N frame and TM-D trip family for the same footprint and breaking capacity.

What compliance documentation does this breaker carry?

It complies with EN/IEC 60947-2, carries suitability for isolation per that standard, and is rated for pollution degree 3 and overvoltage category III. Specific RoHS/REACH/UL declarations are available from the manufacturer on request.

MPN
C10N3TM080C