Schneider Electric C10N44V040 — Residual Current Breakers (RCCB/RCBO)

Schneider Electric C10N44V040 ComPacT NSX100N, 40 A, 90 kA

MPNC10N44V040
Active

Schneider Electric ComPacT NSX series, NSX100N frame, 4P, 40 A at 40 °C, 90 kA Icu at 240 V AC, MicroLogic 4.2 electronic trip unit with integrated earth-leakage protection.

$1,148.69 – $2,155.14Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10N44V040 — Residual Current Protection
ParameterValue
Earth-leakage protection class / typeClass A
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C10N44V040 — Electrical Ratings
ParameterValue
Rated current (In)40 A at 40 °C
Rated operational voltage (Ue)440 V AC 50/60 Hz
Poles description4P
Neutral pole positionLeft
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)500 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIV
Electrical durability50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (operating cycles)50000 cycles
C10N44V040 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeEarth leakage circuit breaker
Product range / familyComPacT
Device short nameNSX100N
C10N44V040 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C10N44V040 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C10N44V040 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

What this breaker delivers

The C10N44V040 is a Schneider Electric ComPacT NSX100N molded-case circuit breaker with a 40 A MicroLogic 4.2 electronic trip unit and integrated earth-leakage protection. It's a 4-pole unit rated for distribution duty, built to EN/IEC 60947-2. At 415 V AC it still holds 50 kA Icu, so it coordinates downstream in a typical 400 V panel.

Trip unit and protection logic

The MicroLogic 4.2 gives you four protection blocks: L (long-time overload), So (short-time short-circuit with fixed delay), I (instantaneous short-circuit), and R (earth-leakage). The earth-leakage is integrated, no add-on module needed. That saves a slot in the panel and one wiring step during commissioning.

Front connections top and bottom — no rear-access requirement, which keeps the panel layout simple. The 35 mm connection pitch matches standard busbar and cable-lug spacing. Neutral is on the left (4P).

Mechanical endurance is 50,000 cycles. Electrical endurance at 440 V In is 30,000 cycles — at half load (In/2) it goes to 50,000. At 690 V In it drops to 10,000 cycles. That's typical for a distribution breaker; it's not a switching device for frequent motor starts, but it handles routine isolation and fault clearing without wearing out early.

Frequently asked questions

What is C10N44V040's breaking capacity at 415 V?

50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2. At 440 V it's also 50 kA Icu, and at 240 V it reaches 90 kA Icu.

MPN
C10N44V040