Schneider Electric C10N4TM100C — Miniature Circuit Breakers (MCB)

Schneider Electric C10N4TM100C ComPacT NSX100N, 100 A, 4P, T

MPNC10N4TM100C
Active

Schneider Electric ComPacT NSX, NSX100N, circuit breaker, 100 A, 4P, TM-D trip unit, 50 kA Icu at 415 V AC, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10N4TM100C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10N4TM100C — Ratings
ParameterValue
Rated current (In)100 A at 50 °C
Poles configuration4P
Breaking capacity90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10N4TM100C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (cycles)50000 cycles
C10N4TM100C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10N4TM100C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10N4TM100C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10N4TM100C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

The C10N4TM100C is a Schneider Electric ComPacT NSX100N 4-pole circuit breaker with a TM-D thermal-magnetic trip unit rated 100 A at 50 °C. The TM-D trip provides L (thermal) overload protection and I (magnetic) short-circuit protection, so it covers both sustained overcurrents and fault events with a single device. Mounts on a backplate in either horizontal or vertical orientation, which gives flexibility in tight enclosures. At 415 V AC — the most common industrial distribution voltage in Europe and much of Asia — this unit delivers 50 kA Icu. At 220/240 V AC it rises to 90 kA, and it still holds 10 kA at 690 V AC. It is also suitable for isolation per that standard — meaning when open, it provides a visible-break isolation gap you can rely on for lockout/tagout.

Integration and mounting notes

Mounts on a backplate — no DIN rail clip on this frame. The 4-pole body is 140 mm wide, 161 mm high, and 86 mm deep, with a 35 mm connection pitch between poles. Neutral is on the left. Front connections on both upside and downside mean you can bus-bar or cable directly without rear access. IK07 impact resistance handles incidental tool strikes during panel assembly. Electrical durability is rated at 50,000 cycles at 440 V at half rated current, and 30,000 cycles at full rated current. Mechanical durability is 50,000 cycles. That is typical for a molded-case breaker in distribution duty — not a switching contactor, but fine for occasional manual switching or automatic reclosing in a backup circuit.

Frequently asked questions

What is the breaking capacity of C10N4TM100C at 415 V?

50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2. This is the N breaking capacity code.

What is the trip unit type and rating on C10N4TM100C?

TM-D thermal-magnetic trip unit rated 100 A at 50 °C. It provides L (thermal) overload protection and I (magnetic) short-circuit protection.

How do I get current pricing and availability for C10N4TM100C?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What compliance standards does C10N4TM100C meet?

Designed to EN/IEC 60947-2, suitable for isolation per that standard. Overvoltage category III, pollution degree 3 per IEC 60664-1. IP40, IK07.