Schneider Electric C10N6TM032C — Miniature Circuit Breakers (MCB)

Schneider Electric C10N6TM032C ComPacT NSX 32A 4P MCCB, 50kA

MPNC10N6TM032C
Active

Schneider Electric ComPacT NSX, C10N6TM032C, 4P MCCB, 32 A TM-D trip unit, 50 kA Icu at 415 V AC, EN/IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10N6TM032C — Identification
ParameterValue
Product nameComPacT NSX
Product rangeComPacT
Product/component typeCircuit breaker
Device applicationDistribution
C10N6TM032C — Ratings
ParameterValue
Rated current (In)32 A at 50 °C
Poles configuration4P
Breaking capacity90 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated service breaking capacity (Ics)90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Rated operational voltage (Ue)690 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Network type (AC/DC)AC
Network frequency50/60 Hz
Utilisation categoryCategory A
Overvoltage categoryIII
C10N6TM032C — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In 20000 cycles at 690 V In/2 10000 cycles at 690 V In
Mechanical durability (cycles)50000 cycles
C10N6TM032C — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
C10N6TM032C — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-50...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
C10N6TM032C — Approvals
ParameterValue
StandardsEN/IEC 60947-2
C10N6TM032C — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

It's built for distribution applications and complies with EN/IEC 60947-2, meaning it's certified for isolation and overcurrent protection in industrial panels. The TM-D trip unit provides thermal overload protection (L) and magnetic short-circuit protection (I), so it handles both sustained overcurrents and fault events in one package.

Breaking capacity — what it means for your fault-current study

50 kA Icu at 380/415 V AC, 90 kA Icu at 220/240 V AC, 10 kA Icu at 660/690 V AC per IEC 60947-2. The utilisation category is A, meaning it's not intended for frequent switching of motor loads — it's a distribution breaker, not a motor-circuit protector. Mechanical durability is 50,000 cycles; electrical durability at 440 V In is 30,000 cycles.

Mounts flat on a backplate in horizontal or vertical orientation. Front connections on both upside and downside. IK07 impact rating means it withstands a 2 J impact — typical for panel-mounted gear that might get bumped during maintenance.

Frequently asked questions

What is C10N6TM032C's breaking capacity at 415 V?

50 kA Icu at 380/415 V AC, 50/60 Hz, per IEC 60947-2.

What compliance documentation does this breaker carry?

It complies with EN/IEC 60947-2 for circuit-breaker performance and isolation, and carries an IK07 impact rating per IEC 62262 and IP40 per IEC 60529.

MPN
C10N6TM032C