Specifications

C10R36M050 — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 95 % Ith (red) for temperature over set point
C10R36M050 — Electrical Ratings
ParameterValue
Rated current (In)50 A at 65 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIII
Electrical durability20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (operating cycles)20000 cycles
C10R36M050 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeCircuit breaker
Product range / familyComPacT
Device short nameNSX100R
C10R36M050 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C10R36M050 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C10R36M050 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

The Schneider Electric C10R36M050 is a ComPacT NSX circuit breaker from the NSX100R frame, fitted with a MicroLogic 6.2 E-M electronic trip unit and rated for motor protection at 50 A at 65 °C.

Above that ambient, derating applies per the manufacturer's curve. The MicroLogic 6.2 E-M provides L (long-time overload), So (short-time short-circuit), I (instantaneous), and G (ground fault) protection, with selectable motor tripping classes 5, 10, 20, and 30. Class 10 is standard for general-purpose motor starting; class 20 or 30 accommodates high-inertia loads like fans or centrifuges that take longer to accelerate. At 690 V AC the rating drops to 45 kA Icu — still substantial for a 690 V motor feeder. The breaker carries a utilisation category A (non-selectively coordinated for short-circuit), so it is suited for standalone motor protection or as part of a cascaded system where the upstream device handles selectivity.

The 105 mm width and 161 mm height fit standard ComPacT NSX cutouts; depth is 86 mm. Five accessory slots are available for auxiliary contacts, shunt trips, or communication modules. The LCD display on the MicroLogic 6.2 E-M shows energy metering, demand values, and event logs — useful for commissioning and troubleshooting.

Frequently asked questions

What is C10R36M050 used for?

It is a motor protection circuit breaker for three-phase AC motor feeders, rated 50 A at 65 °C, with electronic trip unit providing overload, short-circuit, and ground-fault protection.

Where can I buy C10R36M050?

It is sourced and quoted to order through independent distribution against an RFQ; current pricing and availability are confirmed at quote time.

What compliance documentation does C10R36M050 carry?

The breaker is certified to EN/IEC 60947-2, with pollution degree 3 per IEC 60664-1 and IK07 impact resistance per IEC 62262. It operates at altitudes up to 2000 m without derating, and up to 5000 m with derating.

MPN
C10R36M050