Schneider Electric C10V36E100 — Residual Current Breakers (RCCB/RCBO)

C10V36E100 ComPacT NSX 100A, 85kA Icu, MicroLogic 6.2 E

MPNC10V36E100
Active

Schneider Electric ComPacT NSX, NSX100HB1, 3P, 100 A at 40 °C, 85 kA Icu at 500 V AC, MicroLogic 6.2 E trip unit, EN/IEC 60947-2.

$13.51Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

C10V36E100 — Residual Current Protection
ParameterValue
Trip unit technologyElectronic
Local signalling / indicationFlashing LED (green) for ready to operate LED 105 % Ir (red) for overload LED 90 % Ir (orange) for overload
C10V36E100 — Electrical Ratings
ParameterValue
Rated current (In)100 A at 40 °C
Rated operational voltage (Ue)690 V AC 50/60 Hz
Poles description3P
Network typeAC
Network frequency50/60 Hz
Rated insulation voltage (Ui)800 V AC 50/60 Hz
Rated impulse withstand voltage (Uimp)8 kV
Overvoltage categoryIII
Electrical durability20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical durability (operating cycles)20000 cycles
C10V36E100 — Identification
ParameterValue
Product nameComPacT NSX
Product / component typeCircuit breaker
Product range / familyComPacT
Device short nameNSX100HB1
C10V36E100 — Mechanical
ParameterValue
Mounting supportBackplate
Mounting positionHorizontal and vertical Flat on the back
Control typeToggle
C10V36E100 — Environmental
ParameterValue
Operating ambient temperature-25...70 °C
Storage ambient temperature-40...85 °C
IP degree of protectionIP40 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
Relative humidity0...95 %
Operating altitude0...2000 m without derating 2000 m...5000 m with derating
C10V36E100 — Approvals
ParameterValue
StandardsEN/IEC 60947-2

Product details

ComPacT NSX with MicroLogic 6.2 E — 100 A, 85 kA Icu

It carries a MicroLogic 6.2 E electronic trip unit rated 100 A at 40 °C, providing L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground fault) protection per EN/IEC 60947-2. The breaking capacity is 85 kA Icu at 500 V AC 50/60 Hz, 80 kA at 525 V, and 75 kA at 660/690 V — the HB1 code indicates 75 kA at 690 V AC. The IP40 enclosure (IK07 impact resistance) suits indoor panel installation where splash and mechanical knock are limited.

Trip unit and metering capability

It communicates power quality data, demand current and power, protection and alarm settings, time-stamped histories and event tables, maximeters/minimeters, maintenance indicators, and instantaneous/demand values. The LCD display provides local signalling: a flashing green LED for ready-to-operate, red LED at 105 % Ir for overload, and orange LED at 90 % Ir for overload. Pollution degree 3 (IEC 60664-1) and overvoltage category III are specified, confirming suitability for fixed installations in industrial environments.

Durability and environmental limits

Electrical durability varies by load: 20,000 cycles at 440 V In/2, 10,000 cycles at 440 V In, 10,000 cycles at 690 V In/2, and 5,000 cycles at 690 V In. The utilisation category is A (no intentional short-time delay for selectivity with downstream breakers on the same level). Operating altitude is 0 to 2000 m without derating, 2000 m to 5000 m with derating. Relative humidity range is 0 to 95 %.

Frequently asked questions

What is the breaking capacity of C10V36E100?

The breaking capacity is 85 kA Icu at 500 V AC 50/60 Hz, 80 kA Icu at 525 V AC 50/60 Hz, and 75 kA Icu at 660/690 V AC 50/60 Hz, all conforming to IEC 60947-2.

What protection functions does the MicroLogic 6.2 E trip unit provide?

It provides L (long-time overload), S (short-time short-circuit), I (instantaneous short-circuit), and G (ground fault) protection.