Skip to main content
Schneider Electric C10V36M050

C10V36M050 ComPacT NSX 50A, 85kA Icu at 500V AC

MPN C10V36M050
Active

Schneider Electric ComPacT NSX circuit breaker, C10V36M050, 3-pole, 50 A rated at 65 °C, MicroLogic 6.2 E-M electronic trip unit, 85 kA Icu at 500 V AC.

$13.23 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

C10V36M050 key specifications
ParameterValue
Control typeToggle
Display typeLCD display
Trip unit typeElectronic
Main product or component typeCircuit breaker
Voltage690 V AC 50/60 Hz
Insulation voltage ui800 V AC 50/60 Hz
IP ratingIP40
Terminal pitch35 mm
Connection surface topFront
Connection surface bottomFront
Temp storage max85 °C
Temp storage min-40 °C

All specifications

C10V36M050 additional specifications
ParameterValue
Temp operating max70 °C
Temp operating min-25 °C
Storage temperature-40...85 °C
Pollution degreeclass 3
Depth86 mm
Width105 mm
Height161 mm
Electrical life cycles20000 cycles at 440 V In/2 10000 cycles at 440 V In 10000 cycles at 690 V In/2 5000 cycles at 690 V In
Mechanical life cycles20000 cycles
ApplicationMotor protection
Operating temperature-25...70 °C

Product details

The C10V36M050 is a Schneider Electric ComPacT NSX circuit breaker, 3-pole, with a MicroLogic 6.2 E-M electronic trip unit rated at 50 A at 65 °C. It's built for motor protection, not just feeder duty — the E-M trip unit gives you adjustable overload (L), short-time (So), instantaneous (I), and ground-fault (G) protection curves, with motor tripping classes 10, 5, 20, and 30 selectable. The 85 kA Icu at 500 V AC is the interrupting rating that governs fault clearing in a motor branch circuit; at 690 V AC it still holds 75 kA Icu, which covers most industrial motor starters. The part sits in the ComPacT NSX family, so it shares the standard backplate mount, front connections, and the 105 mm wide footprint that fits a typical MCC bucket or panel layout.

Mounting and integration — backplate, front connections, 105 mm wide

The 105 mm width (W) and 161 mm height (H) with 86 mm depth (D) fit standard panel layouts. Overvoltage category III covers fixed-installation distribution boards.

Standards and approvals — EN/IEC 60947-2, IK07

The IK07 impact rating per IEC 62262 means the enclosure withstands a 2 J impact — enough for a tool drop in a panel. The LCD display on the trip unit shows metering data, protection settings, and event logs, which is useful during commissioning without needing a separate communication gateway.

MPN